Conference Rooms
Discover the energy-saving potential of your conference room with Rayzeek’s occupancy sensor design guide.

Maximize Energy Efficiency in Conference Rooms with Occupancy Sensors
Conference rooms are integral to the functioning of any commercial building, serving as the hub for meetings, presentations, and brainstorming sessions. These rooms are often equipped with high-intensity lighting to ensure visibility during presentations and discussions. However, due to their intermittent usage, they are prone to high energy wastage. Lights are often left on when the room is vacant, leading to unnecessary energy consumption.
Moreover, the sporadic usage of conference rooms means that they often remain vacant for extended periods, leading to unnecessary energy consumption if the lights are left on. This wastage not only impacts the building’s energy efficiency but also contributes to higher operational costs.
With Rayzeek’s occupancy sensors, you can transform your conference room into an energy-efficient space, meeting the requirements of energy codes and contributing to a greener environment.
Enerji Kodlarıyla Uyum Sağlayın

Uluslararası Enerji Koruma Kodu (IECC), binalarda enerji verimliliği için asgari tasarım ve inşaat gerekliliklerini belirlemek üzere Uluslararası Kod Konseyi (ICC) tarafından geliştirilen bir model koddur. IECC, enerji koruma uygulamaları ve teknolojilerindeki en son gelişmeleri dahil etmek için her üç yılda bir güncellenir.
IECC, Neden Önemsemelisiniz?
IECC, Amerika Birleşik Devletleri genelinde eyaletler ve belediyeler tarafından yaygın olarak benimsenmektedir. IECC, bina kabuğu (duvarlar, çatılar ve pencereler), ısıtma ve soğutma sistemleri ile aydınlatma sistemleri dahil olmak üzere enerji kullanımının çeşitli yönlerini kapsar.
IECC, çeşitli alanlarda kullanılmayan mekanlardaki enerji israfını en aza indirmek için doluluk sensörleri gibi belirli aydınlatma kontrollerini zorunlu kılar.

ANSI/ASHRAE/IES Standard 90.1, Düşük Katlı Konut Dışındaki Siteler ve Binalar için Enerji Standardı, Amerikan Isıtma, Soğutma ve Klima Mühendisleri Derneği (ASHRAE) tarafından yayımlanan ve yaygın olarak tanınan bir enerji standardıdır.
ASHRAE 90.1, Neden Önemsemelisiniz?
ASHRAE 90.1, Amerika Birleşik Devletleri genelinde bina enerji kodları için bir kıyaslama ölçütü olarak kullanılır ve ticari binaların bileşenlerinin (bina kabukları, HVAC sistemleri, su ısıtma sistemleri ve aydınlatma sistemleri dahil) enerji verimli performansı için asgari gereklilikleri ana hatlarıyla belirleyen IECC içinde bir uyumluluk yolu olarak hizmet eder.
ASHRAE 90.1 standardı, belirli alanlarda doluluk sensörlerinin kullanımını da içeren asgari aydınlatma kontrol gerekliliklerini ve izin verilen maksimum aydınlatma güç yoğunluklarını belirtir.

California Yapı Standartları Kodu'nun 6. Bölümü, 24. Başlık, resmi olarak Konut ve Konut Dışı Binalar için Bina Enerji Verimliliği Standartları olarak bilinir. 24. Başlık, California Enerji Komisyonu tarafından yönetilir ve yeni enerji verimliliği teknolojilerini ve yöntemlerini yansıtacak şekilde periyodik olarak güncellenir.
Title 24, Neden Önemsemelisiniz?
Title 24, sıkı gereklilikleriyle bilinir ve genellikle Amerika Birleşik Devletleri'ndeki birçok diğer enerji kodundakinden daha katı olarak kabul edilir. Title 24, ısıtma, havalandırma, klima (HVAC), su ısıtma ve aydınlatma dahil olmak üzere bina inşaatının tüm yönleri için katı enerji performans standartlarını zorunlu kılar.
Title 24, enerji israfını önlemek için ticari binaların belirli alanlarında oda doluluk durumuna göre aydınlatmayı ayarlayan doluluk sensörlerinin kurulumunu gerektirir.
Eyaletlere Göre Enerji Kodu Kabulü

Ayrıntılı tabloyu görmek için genişletin ↓
| Eyalet | Mevcut Ticari Kod | Ticari Kod Verimlilik Kategorisi |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Eyalet genelinde yok | Eyalet genelinde kod yok |
| Arizona | Yerel yönetim kuralı | <90.1-2007 |
| Arkansas | 2009 IECC ve 90.1-2007 | 90.1-2007 |
| California | 2022 Bina Enerji Verimliliği Standartları | 90.1-2019 |
| Colorado | Yerel yönetim kuralı | Eyalet genelinde kod yok |
| Connecticut | 2021 IECC ve 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC ve 90.1-2016 | 90.1-2013 |
| Columbia Bölgesi | 90.1-2013^ | 90.1-2019 |
| Florida | 2021 IECC ve 90.1-2019^ | 90.1-2016 |
| Georgia | 2015 IECC ve 90.1-2013^ | 90.1-2013 |
| Hawaii | Yerel yönetim kuralı | 90.1-2013 |
| Idaho | 2018 IECC ve 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC ve 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC ve 90.1-2010 | 90.1-2007 |
| Kansas | Yerel yönetim kuralı | Eyalet genelinde kod yok |
| Kentucky | 2012 IECC ve 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC ve 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC ve 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC ve 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC ve 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Eyalet genelinde yok | Eyalet genelinde kod yok |
| Missouri | Yerel yönetim kuralı | Eyalet genelinde kod yok |
| Montana | 2021 IECC ve 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC ve 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC ve 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC ve 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| New Mexico | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| New York | 2018 IECC ve 90.1-2016^ | 90.1-2016 |
| North Carolina | 2015 IECC ve 90.1-2013^ | 90.1-2010 |
| North Dakota | Yerel yönetim kuralı | Eyalet genelinde kod yok |
| Ohio | 2021 IECC ve 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC ve 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC ve 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC ve 90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC ve 90.1-2007 | 90.1-2007 |
| South Dakota | Yerel yönetim kuralı | Eyalet genelinde kod yok |
| Tennessee | 2021 IECC ve 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC ve 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington Eyaleti Enerji Kodu | 90.1-2019 |
| Tennessee | 2012 IECC ve 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC ve 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC ve 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington Eyaleti Enerji Kodu | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC ve 90.1-2013^ | 90.1-2010 |
| Wyoming | Yerel yönetim kuralı | Eyalet genelinde kod yok |
- ^ Enerji verimliliğini etkileyen bir değişiklik, DOE Prototip Bina Modelleri kullanılarak nicelendirilebildiğinde, analizde yer almıştır.
- Hem IECC'yi hem de 90.1'i benimseyen eyaletler için, bu çalışmada IECC kodu genellikle eyaletin geçerli kodu olarak analiz edilir; IECC'ye kapsamlı değişiklikler yapan eyaletler hariç.
Design Guide Key Concepts for Conference Rooms
Designing an energy-efficient lighting control solution for conference rooms involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

Designing an energy-efficient lighting system for a conference room involves strategic placement of occupancy sensors to ensure comprehensive coverage. Here are some guidelines to consider:
- Giriş Kapsamı: Install a wall-mounted sensor near the entrance to detect when someone enters or exits the room. This sensor should be positioned high enough to avoid obstruction from the open door and should not directly face the entrance to avoid false triggers from movement outside the room.
- Table Coverage: Place a ceiling-mounted sensor above the conference table to detect occupancy in the main area of the room. This sensor should be positioned centrally to ensure comprehensive coverage.
- Presentation Area Coverage: If your conference room has a dedicated presentation area, consider installing an additional wall-mounted sensor to cover this space. This sensor should be positioned to avoid any potential obstructions, such as screens or projectors.
- Wall Control: Install a wall control unit near the entrance for manual override or adjustments of the lighting settings. This control should be easily accessible upon entering or exiting the room.
- Avoidance of Obstructions and Interference: Ensure that sensors are not placed near air vents to prevent interference from air flow or vibrations. Also, consider the height and placement of furniture to avoid blocking the sensor’s field of view.
- Integration with Existing Systems: Our occupancy sensors can be integrated with existing lighting systems for seamless operation. They can also be programmed to turn off all lights after a certain period of inactivity, further enhancing energy efficiency.
Öne Çıkan Ürünler ve Çözümler
Temel özellikler şunları içerir:
- Tüm aydınlatma için entegre manuel AÇMA/KAPAMA kontrolü
- Boşaltma sensörleri (Yalnızca Manuel AÇMA): Işıklar yalnızca manuel olarak açılmalıdır
- Ayarlanabilir zaman gecikmesi, aydınlatma 15 dakika sonra otomatik olarak tamamen KAPANIR
- Ek olarak: Yeniden kablolama yapmadan kontrol alanını genişletmek için çoklu konumlu kablosuz kitler
- Ek olarak: Hem yeni inşaat hem de renovasyon projeleri için birden fazla kablolama seçeneği mevcuttur.

Zorunlu Hükümleri Karşılar
IECC – 2011
C405.2.1 Kullanıcı sensör kontrolleri
Alandaki ışıkları kontrol etmek için kullanıcı sensör kontrolleri kurulmalıdır.
C405.2.1.1 Kullanıcı sensör kontrol işlevleri
- Manuel açma veya % gücüne kadar kısmi açma.
- Tüm kullanıcılar alanı terk ettikten sonra 20 dakika içinde tamamen kapanma
- Işıkları kapatmak için bir manuel kontrol.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 b Restricted to manual ON
None of the lighting shall be automatically turned on
9.4.1.1 c Restricted to partial automatic ON
No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on
** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.
9.4.1.1 h Automatic full OFF control
Alandaki tüm aydınlatma, tüm kullanıcılar alanı terk ettikten sonra 20 dakika içinde otomatik olarak kapatılmalıdır
Title 24 – 2022
130.1 (a) Manuel alan kontrolleri.
Tavan yüksekliğindeki bölmelerle çevrelenen her alan, o alandaki aydınlatmanın manuel olarak açılıp kapatılmasına olanak tanıyan aydınlatma kontrolleri sağlamalıdır.
130.1 (c) KAPAMA Kontrolleri.
Aydınlatma, kontrol alanı boşaldıktan sonra 20 dakika veya daha kısa sürede tüm aydınlatmayı otomatik olarak KAPATMAK için kullanıcı algılama kontrolleriyle kontrol edilmelidir. Bu kontroller şu işlevlerden birini yerine getirmelidir:
- A. Kullanıcı algılama kontrolleri (eğer 130.1(b) çok seviyeli aydınlatma kontrolleri gerektirmiyorsa); veya
- B. Kısmi AÇMA kullanıcı algılama kontrolleri, veya
- C. Boşluk algılama kontrolleri, tüm aydınlatmanın yalnızca manuel AÇIK girişine yanıt verdiği yer
Sizi dinliyoruz.
Rayzeek, sizin için özel bir enerji tasarruflu aydınlatma çözümü tasarlamanıza ve sunmanıza yardımcı olsun.