Restaurants
Restoranlar için enerji tasarrufu tasarım kılavuzunu keşfedin; burada verimli aydınlatma kontrolü, enerji tüketimini azaltırken davetkar bir atmosfer yaratmanın anahtarıdır.

Harness the Power of Automated Lighting Control for Your Restaurant
Restaurants are bustling spaces, filled with the aroma of delicious food, the clinking of cutlery, and the hum of conversation. However, behind the scenes, they are also high-energy consumption areas, particularly when it comes to lighting. From the warm ambient lighting that sets the mood, to the bright task lighting in the kitchen, and the safety lighting in storage areas, restaurants use a variety of lighting types, all of which consume significant amounts of energy.
Moreover, the irregular and extended operating hours of restaurants often lead to lights being left on unnecessarily, resulting in high energy waste. This not only impacts the restaurant’s bottom line but also contributes to the larger issue of energy conservation.
To address this, Rayzeek offers a solution in the form of occupancy sensors. These sensors can automatically control lighting based on the presence or absence of people, reducing energy consumption significantly. In a restaurant setting, this means lights in the dining area, kitchen, restrooms, and storage areas can be automatically turned off when these spaces are not in use, without any manual intervention. This not only saves energy but also complies with energy efficiency requirements set by US Energy Codes/Energy standards.
Enerji Kodlarıyla Uyum Sağlayın

Uluslararası Enerji Koruma Kodu (IECC), binalarda enerji verimliliği için asgari tasarım ve inşaat gerekliliklerini belirlemek üzere Uluslararası Kod Konseyi (ICC) tarafından geliştirilen bir model koddur. IECC, enerji koruma uygulamaları ve teknolojilerindeki en son gelişmeleri dahil etmek için her üç yılda bir güncellenir.
IECC, Neden Önemsemelisiniz?
IECC, Amerika Birleşik Devletleri genelinde eyaletler ve belediyeler tarafından yaygın olarak benimsenmektedir. IECC, bina kabuğu (duvarlar, çatılar ve pencereler), ısıtma ve soğutma sistemleri ile aydınlatma sistemleri dahil olmak üzere enerji kullanımının çeşitli yönlerini kapsar.
IECC, çeşitli alanlarda kullanılmayan mekanlardaki enerji israfını en aza indirmek için doluluk sensörleri gibi belirli aydınlatma kontrollerini zorunlu kılar.

ANSI/ASHRAE/IES Standard 90.1, Düşük Katlı Konut Dışındaki Siteler ve Binalar için Enerji Standardı, Amerikan Isıtma, Soğutma ve Klima Mühendisleri Derneği (ASHRAE) tarafından yayımlanan ve yaygın olarak tanınan bir enerji standardıdır.
ASHRAE 90.1, Neden Önemsemelisiniz?
ASHRAE 90.1, Amerika Birleşik Devletleri genelinde bina enerji kodları için bir kıyaslama ölçütü olarak kullanılır ve ticari binaların bileşenlerinin (bina kabukları, HVAC sistemleri, su ısıtma sistemleri ve aydınlatma sistemleri dahil) enerji verimli performansı için asgari gereklilikleri ana hatlarıyla belirleyen IECC içinde bir uyumluluk yolu olarak hizmet eder.
ASHRAE 90.1 standardı, belirli alanlarda doluluk sensörlerinin kullanımını da içeren asgari aydınlatma kontrol gerekliliklerini ve izin verilen maksimum aydınlatma güç yoğunluklarını belirtir.

California Yapı Standartları Kodu'nun 6. Bölümü, 24. Başlık, resmi olarak Konut ve Konut Dışı Binalar için Bina Enerji Verimliliği Standartları olarak bilinir. 24. Başlık, California Enerji Komisyonu tarafından yönetilir ve yeni enerji verimliliği teknolojilerini ve yöntemlerini yansıtacak şekilde periyodik olarak güncellenir.
Title 24, Neden Önemsemelisiniz?
Title 24, sıkı gereklilikleriyle bilinir ve genellikle Amerika Birleşik Devletleri'ndeki birçok diğer enerji kodundakinden daha katı olarak kabul edilir. Title 24, ısıtma, havalandırma, klima (HVAC), su ısıtma ve aydınlatma dahil olmak üzere bina inşaatının tüm yönleri için katı enerji performans standartlarını zorunlu kılar.
Title 24, enerji israfını önlemek için ticari binaların belirli alanlarında oda doluluk durumuna göre aydınlatmayı ayarlayan doluluk sensörlerinin kurulumunu gerektirir.
Eyaletlere Göre Enerji Kodu Kabulü

Ayrıntılı tabloyu görmek için genişletin ↓
| Eyalet | Mevcut Ticari Kod | Ticari Kod Verimlilik Kategorisi |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Eyalet genelinde yok | Eyalet genelinde kod yok |
| Arizona | Yerel yönetim kuralı | <90.1-2007 |
| Arkansas | 2009 IECC ve 90.1-2007 | 90.1-2007 |
| California | 2022 Bina Enerji Verimliliği Standartları | 90.1-2019 |
| Colorado | Yerel yönetim kuralı | Eyalet genelinde kod yok |
| Connecticut | 2021 IECC ve 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC ve 90.1-2016 | 90.1-2013 |
| Columbia Bölgesi | 90.1-2013^ | 90.1-2019 |
| Florida | 2021 IECC ve 90.1-2019^ | 90.1-2016 |
| Georgia | 2015 IECC ve 90.1-2013^ | 90.1-2013 |
| Hawaii | Yerel yönetim kuralı | 90.1-2013 |
| Idaho | 2018 IECC ve 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC ve 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC ve 90.1-2010 | 90.1-2007 |
| Kansas | Yerel yönetim kuralı | Eyalet genelinde kod yok |
| Kentucky | 2012 IECC ve 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC ve 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC ve 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC ve 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC ve 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Eyalet genelinde yok | Eyalet genelinde kod yok |
| Missouri | Yerel yönetim kuralı | Eyalet genelinde kod yok |
| Montana | 2021 IECC ve 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC ve 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC ve 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC ve 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| New Mexico | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| New York | 2018 IECC ve 90.1-2016^ | 90.1-2016 |
| North Carolina | 2015 IECC ve 90.1-2013^ | 90.1-2010 |
| North Dakota | Yerel yönetim kuralı | Eyalet genelinde kod yok |
| Ohio | 2021 IECC ve 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC ve 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC ve 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC ve 90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC ve 90.1-2007 | 90.1-2007 |
| South Dakota | Yerel yönetim kuralı | Eyalet genelinde kod yok |
| Tennessee | 2021 IECC ve 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC ve 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington Eyaleti Enerji Kodu | 90.1-2019 |
| Tennessee | 2012 IECC ve 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC ve 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC ve 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC ve 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington Eyaleti Enerji Kodu | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC ve 90.1-2013^ | 90.1-2010 |
| Wyoming | Yerel yönetim kuralı | Eyalet genelinde kod yok |
- ^ Enerji verimliliğini etkileyen bir değişiklik, DOE Prototip Bina Modelleri kullanılarak nicelendirilebildiğinde, analizde yer almıştır.
- Hem IECC'yi hem de 90.1'i benimseyen eyaletler için, bu çalışmada IECC kodu genellikle eyaletin geçerli kodu olarak analiz edilir; IECC'ye kapsamlı değişiklikler yapan eyaletler hariç.
Design Guide Key Concepts for Restaurants
Designing an energy-efficient lighting control solution for restaurants involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In a restaurant setting, the placement of occupancy sensors can be tailored to the specific needs of each area. Here’s a possible design guide:
- Dining Area: Ceiling occupancy sensors can be installed to cover the main dining area. These sensors can automatically turn on the lights when guests are seated and turn them off when the area is vacant. To avoid any blind spots, ensure that the coverage areas of these sensors overlap. This ensures that the dining area is always well-lit when needed, enhancing the dining experience while saving energy.
- Kitchen: Given the high activity level in restaurant kitchens, wall occupancy/vacancy sensors can be installed. These sensors can be manually turned on at the start of the day and when the kitchen is not in use, especially during off-peak hours, the lights can be automatically turned off, reducing unnecessary energy consumption.
- Tuvaletler: Restrooms in restaurants are ideal for ceiling occupancy sensors. These sensors can automatically control lighting based on occupancy, ensuring lights are not left on unnecessarily.
- Storage and Utility Rooms: In storage and utility rooms, where occupancy is sporadic, wall occupancy/vacancy sensors can be installed. These sensors can automatically turn the lights on when someone enters the room and off when the room is vacant.
- Manuel Kontrol: All lighting can be manually turned ON/OFF using the integrated controls in our occupancy/vacancy sensors. This provides flexibility for staff to control lighting based on specific needs or situations.
Öne Çıkan Ürünler ve Çözümler
Temel özellikler şunları içerir:
- Tüm aydınlatma için entegre manuel AÇMA/KAPAMA kontrolü
- Boşaltma sensörleri (Yalnızca Manuel AÇMA): Işıklar yalnızca manuel olarak açılmalıdır
- Ayarlanabilir zaman gecikmesi, aydınlatma 15 dakika sonra otomatik olarak tamamen KAPANIR
- Ek olarak: Yeniden kablolama yapmadan kontrol alanını genişletmek için çoklu konumlu kablosuz kitler
- Ek olarak: Hem yeni inşaat hem de renovasyon projeleri için birden fazla kablolama seçeneği mevcuttur.

Zorunlu Hükümleri Karşılar
IECC – 2011
C405.2.1 Kullanıcı sensör kontrolleri
Alandaki ışıkları kontrol etmek için kullanıcı sensör kontrolleri kurulmalıdır.
C405.2.1.1 Kullanıcı sensör kontrol işlevleri
- Manuel açma veya % gücüne kadar kısmi açma.
- Tüm kullanıcılar alanı terk ettikten sonra 20 dakika içinde tamamen kapanma
- Işıkları kapatmak için bir manuel kontrol.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 b Restricted to manual ON
None of the lighting shall be automatically turned on
9.4.1.1 c Restricted to partial automatic ON
No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on
** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.
9.4.1.1 H Otomatik tam KAPAMA kontrolü
Alandaki tüm aydınlatma, tüm kullanıcılar alanı terk ettikten sonra 20 dakika içinde otomatik olarak kapatılmalıdır
Title 24 – 2022
130.1 (a) Manuel alan kontrolleri.
Tavan yüksekliğindeki bölmelerle çevrelenen her alan, o alandaki aydınlatmanın manuel olarak açılıp kapatılmasına olanak tanıyan aydınlatma kontrolleri sağlamalıdır.
130.1 (c) KAPAMA Kontrolleri.
Aydınlatma, kontrol alanı boşaldıktan sonra 20 dakika veya daha kısa sürede tüm aydınlatmayı otomatik olarak KAPATMAK için kullanıcı algılama kontrolleriyle kontrol edilmelidir. Bu kontroller şu işlevlerden birini yerine getirmelidir:
- A. Kullanıcı algılama kontrolleri (eğer 130.1(b) çok seviyeli aydınlatma kontrolleri gerektirmiyorsa); veya
- B. Kısmi AÇMA kullanıcı algılama kontrolleri, veya
- C. Boşluk algılama kontrolleri, tüm aydınlatmanın yalnızca manuel AÇIK girişine yanıt verdiği yer
Sizi dinliyoruz.
Rayzeek, sizin için özel bir enerji tasarruflu aydınlatma çözümü tasarlamanıza ve sunmanıza yardımcı olsun.