{"id":17996,"date":"2024-05-21T08:41:22","date_gmt":"2024-05-21T08:41:22","guid":{"rendered":"https:\/\/staging.rayzeek.com\/?page_id=17996"},"modified":"2024-06-05T02:22:38","modified_gmt":"2024-06-05T02:22:38","slug":"corridor-design-guide","status":"publish","type":"page","link":"https:\/\/staging.rayzeek.com\/sv\/corridor-design-guide","title":{"rendered":"Designguide f\u00f6r korridor"},"content":{"rendered":"<div class=\"wp-block-cover alignfull is-light rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-17998\" alt=\"\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg 1920w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-300x78.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-1024x267.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-768x200.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-1536x400.jpg 1536w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-18x5.jpg 18w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"corridors\">Corridors<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">Discover the energy-saving potential of corridors with Rayzeek&#8217;s occupancy sensor design guide. Uncover the power of automated lighting control in your commercial building&#8217;s passageways.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4.jpg\" alt=\"\" class=\"wp-image-17997\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"lighting-the-way-to-energy-efficiency-in-corridors\">Lighting the Way to Energy Efficiency in Corridors<\/h2>\n\n<p>Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption. These spaces typically use fluorescent or LED lighting, which, while energy-efficient, can still contribute to high energy costs when left on unnecessarily.<\/p>\n\n<p>The challenge lies in the fact that corridors are intermittently occupied, with periods of high foot traffic interspersed with times of vacancy. Traditional manual lighting controls can lead to lights being left on during these vacant periods, resulting in unnecessary energy waste.<\/p>\n\n<p>By integrating our occupancy sensors into your corridor lighting system, you can ensure that lights are only on when needed, saving energy and reducing costs. Our sensors, including wall and ceiling-mounted options, are designed to comply with US Energy Codes, making them an essential component in meeting energy efficiency requirements for commercial buildings.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Meet the Energy Codes<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>The International Energy Conservation Code (IECC) is a model code developed by the International Code Council (ICC) to establish minimum design and construction requirements for energy efficiency in buildings. The IECC is updated every three years to incorporate the latest in energy conservation practices and technologies.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC, Why You Should Care<\/h3>\n\n<p>IECC is widely adopted by states and municipalities across the United States. IECC covers various aspects of energy use, including the building envelope (walls, roofs, and windows), heating and cooling systems, and lighting systems.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>IECC mandates specific lighting controls, such as occupancy sensors, to minimize energy wastage in unoccupied spaces in various areas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>ANSI\/ASHRAE\/IES Standard 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, is a widely recognized energy standard published by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1, Why You Should Care<\/h3>\n\n<p>ASHRAE 90.1 is used as a benchmark for building energy codes across the United States and serves as a compliance path within the IECC which outlines minimum requirements for the energy-efficient performance of commercial buildings&#8217; components including building envelopes, HVAC systems, water heating systems, and lighting systems. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>ASHRAE 90.1 standard specifies maximum allowable lighting power densities and minimum lighting control requirements, including the use of occupancy sensors in specific areas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>Title 24, part 6 of the California Building Standards Code, officially known as the Building Energy Efficiency Standards for Residential and Nonresidential Buildings, Title 24 is administered by the California Energy Commission and is updated periodically to reflect new energy efficiency technologies and methods.<\/p>\n\n<h3 class=\"wp-block-heading\">Title 24, Why You Should Care<\/h3>\n\n<p>Title 24 is known for its rigorous requirements, often considered more stringent than those found in many other energy codes across the United States. Title 24 mandates strict energy performance standards for all aspects of building construction, which includes heating, ventilation, air conditioning (HVAC), water heating, and lighting.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Title 24 requires the installation of occupancy sensors that adjust lighting based on room occupancy in specific areas of commercial buildings to ensure that energy is not wasted.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Energy Code Adoption by State<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">Expand to see the detailed table \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>State<\/th><th>Current Commercial Code<\/th><th>Commercial Code Efficiency Category<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alaska<\/td><td>None statewide<\/td><td>No statewide code<\/td><\/tr><tr><td>Arizona<\/td><td>Home rule<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>2009 IECC and 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>California<\/td><td>2022 Building Energy Efficiency Standards<\/td><td>90.1-2019<\/td><\/tr><tr><td>Colorado<\/td><td>Home rule<\/td><td>No statewide code<\/td><\/tr><tr><td>Connecticut<\/td><td>2021 IECC and 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>2018 IECC and 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>District of Columbia<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Florida<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Georgia<\/td><td>2015 IECC and 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Hawaii<\/td><td>Home rule<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>2018 IECC and 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>2021 IECC and 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>2012 IECC and 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Home rule<\/td><td>No statewide code<\/td><\/tr><tr><td>Kentucky<\/td><td>2012 IECC and 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Louisiana<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>2015 IECC and 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>2018 IECC and 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Michigan<\/td><td>2015 IECC and 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Mississippi<\/td><td>None statewide<\/td><td>No statewide code<\/td><\/tr><tr><td>Missouri<\/td><td>Home rule<\/td><td>No statewide code<\/td><\/tr><tr><td>Montana<\/td><td>2021 IECC and 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>2018 IECC and 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>2018 IECC and 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Hampshire<\/td><td>2018 IECC and 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>New Mexico<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>New York<\/td><td>2018 IECC and 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>North Carolina<\/td><td>2015 IECC and 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>North Dakota<\/td><td>Home rule<\/td><td>No statewide code<\/td><\/tr><tr><td>Ohio<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>2006 IECC and 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oregon<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pennsylvania<\/td><td>2018 IECC and 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>2018 IECC and 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>South Carolina<\/td><td>2009 IECC and 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>South Dakota<\/td><td>Home rule<\/td><td>No statewide code<\/td><\/tr><tr><td>Tennessee<\/td><td>2021 IECC and 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>2015 IECC and 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>2018 Washington State Energy Code<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>2012 IECC and 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>2015 IECC and 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>2018 IECC and 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>2018 Washington State Energy Code<\/td><td>90.1-2019<\/td><\/tr><tr><td>West Virginia<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>2015 IECC and 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Home rule<\/td><td>No statewide code<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.<\/li>\n\n<li>For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Sensor Solutions<\/h4>\n\n<p>Find out how Rayzeek can solve your energy saving challenges.<\/p>\n\n<a  href=\"https:\/\/staging.rayzeek.com\/sv\/products\"><div class=\"offering_button\"><p>View All Offerings<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-corridors\">Design Guide Key Concepts for Corridors<\/h2>\n\n<p>Designing an energy-efficient lighting control solution for corridors involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2.jpg\" alt=\"\" class=\"wp-image-18000\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>In a corridor, the primary goal is to ensure safe and well-lit passage for occupants while minimizing energy waste and all potential access points and the entire length of the corridor are covered by the sensors.  Here are some design considerations:<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>Sensor Placement<\/strong>: For long corridors, multiple sensors may be required. Ceiling-mounted sensors can be placed at regular intervals along the length of the corridor to ensure comprehensive coverage. Alternatively, wall-mounted sensors can be placed at both ends of the corridor, with their coverage areas overlapping in the middle to avoid any blind spots. Also, consider the height and range of the sensors to ensure they can effectively detect movement across the entire corridor.<\/li>\n\n<li><strong>Sensor Type<\/strong>: Depending on the ceiling height and the presence of any potential obstructions, either ceiling-mounted or wall-mounted sensors can be used. Rayzeek&#8217;s ceiling sensors offer automatic ON and full OFF functionality, while our wall sensors provide manual ON and full OFF functionality.<\/li>\n\n<li><strong>Additional Manual Controls<\/strong>: In addition to occupancy sensors, manual controls can be integrated for instances where manual override is necessary. These controls can be conveniently located near entrances or exits.<\/li>\n\n<li><strong>Avoiding False Triggers<\/strong>: Sensors should be placed such that they do not directly face doors leading to other spaces, external light sources and air vents, as this could lead to false triggers when movement is detected in these adjacent spaces.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Featured Products &amp; Solutions<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/staging.rayzeek.com\/sv\/produkt-kategori\/motion-sensors\/wall-mount-motion-sensors\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Wall Sensor Switches<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ020\/021 Motion Sensor Switches<\/h4>\n\n<ul class=\"wp-block-list\"><li>2-wire, 3-wire, 4-wires wiring options <\/li>\n\n<li>Occupancy, Vacancy, Manual ON\/OFF<\/li>\n\n<li>Adjustive time delay and ambient light control<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/staging.rayzeek.com\/sv\/produkt-kategori\/wireless-motion-sensors\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Multi-Location Wireless Wall Sensors<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ020A\/021A + RZ022W Kits<\/h4>\n\n<ul class=\"wp-block-list\"><li>Hardwired RZ021A\/022A occupancy sensor switch<\/li>\n\n<li>Wireless companion switch (RZ022W) for multi-location control<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/staging.rayzeek.com\/sv\/produkt-kategori\/occupancy-sensors\/ceiling-mount\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Ceiling Occupancy Sensors<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>Hardwired occupancy sensors<\/li>\n\n<li>Auto ON, auto OFF <\/li>\n\n<li>Line voltage and Low voltage available<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Core features included:<\/h3>\n\n<ul class=\"wp-block-list\"><li>Integrated manual ON\/OFF control for all lighting<\/li>\n\n<li>Vacancy sensors (Manual ON only): Lights must be turned on manually only<\/li>\n\n<li>Adjustable time-delay, lighting is automatically turned full OFF after 15mins<\/li>\n\n<li>Additional: multi-location wireless kits to expand the control range without re-wring<\/li>\n\n<li>Additional: multiple wiring options available for both new constructions and retrofit projects.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3.jpg\" alt=\"\" class=\"wp-image-18001\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Meets the Mandatory Provisions<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC &#8211; 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Occupant sensor controls<\/h4>\n\n<p>Occupant sensor controls shall be installed to control lights in the space.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Occupant sensor control functions<\/h4>\n\n<ul class=\"wp-block-list\"><li>Manual on or partial on to no more than 50% power.<\/li>\n\n<li>Full off within 20 minutes after all occupants have left the space<\/li>\n\n<li>A manual control to turn off the lights.<\/li><\/ul>\n\n<p>Full automatic-on controls with no manual control are permitted in corridors where manual operation would endanger occupant safety or security.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405214-occupant-sensor-control-function-in-corridors\">C405.2.1.4 Occupant sensor control function in corridors.<\/h4>\n\n<p>Occupant sensor controls in corridors shall uniformly reduce lighting power to an occupied setpoint not more than 50 percent offull power within 20 minutes after all occupants have left the space.<\/p>\n\n<p>Exception: Corridors provided with less than two footcandles of illumination on the floor at the darkest point with all lights on.<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 &#8211; 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"9411-a-local-control\">9.4.1.1 a Local control<\/h4>\n\n<p>There shall be one or more manual lighting control device that provides ON and OFF control<br>of all lighting in the space.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-g-automatic-reduction-control\">9.4.1.1 g Automatic reduction control<\/h4>\n\n<p>The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 h Automatic full OFF control<\/h4>\n\n<p>All lighting in the space shall be automatically shut off within 15 minutes of all occupants leaving the space.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-i-scheduled-shutoff\">9.4.1.1 i Scheduled shutoff<\/h4>\n\n<p>All lighting in the space shall be automatically shut off during periods when the space is scheduled to be unoccupied.<\/p>\n\n<p>** NOTE: At least one 9.4.1.1 h or 9.4.1.1 i shall be implemented.<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">Title 24 &#8211; 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) Manual area controls.<\/h4>\n\n<p>Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Shut-OFF Controls.<\/h4>\n\n<p>In corridors, lighting shall be controlled by Full or partial-OFF occupant sensing controls that separately reduce the lighting power in each space by at least 50 percent when the space is unoccupied. The occupant sensing controls shall be capable of automatically turning the lighting fully ON only in the separately controlled space, and shall be automatically activated from all designed paths of egress.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Let us hear you.<\/h3>\n\n<p>Let Rayzeek help design and deliver a bespoke energy-saving lighting solution for you.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/sv\/wp-json\/wp\/v2\/pages\/17996#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/sv\/wp-json\/wp\/v2\/pages\/17996#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Submit\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"sv\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption.<\/p>","protected":false},"author":1,"featured_media":17998,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-17996","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Corridor Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/staging.rayzeek.com\/sv\/corridor-design-guide\" \/>\n<meta property=\"og:locale\" content=\"sv_SE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Corridor Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/staging.rayzeek.com\/sv\/corridor-design-guide\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Ber\u00e4knad l\u00e4stid\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minuter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide\",\"url\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide\",\"name\":\"Corridor Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T08:41:22+00:00\",\"dateModified\":\"2024-06-05T02:22:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide#breadcrumb\"},\"inLanguage\":\"sv-SE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/staging.rayzeek.com\/corridor-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide#primaryimage\",\"url\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/staging.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Corridor Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/staging.rayzeek.com\/#website\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/staging.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sv-SE\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Corridor Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/staging.rayzeek.com\/sv\/corridor-design-guide","og_locale":"sv_SE","og_type":"article","og_title":"Corridor Energy Code Design Guide - Rayzeek","og_description":"Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption.","og_url":"https:\/\/staging.rayzeek.com\/sv\/corridor-design-guide","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:38+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Ber\u00e4knad l\u00e4stid":"4 minuter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/staging.rayzeek.com\/corridor-design-guide","url":"https:\/\/staging.rayzeek.com\/corridor-design-guide","name":"Corridor Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/staging.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/staging.rayzeek.com\/corridor-design-guide#primaryimage"},"image":{"@id":"https:\/\/staging.rayzeek.com\/corridor-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg","datePublished":"2024-05-21T08:41:22+00:00","dateModified":"2024-06-05T02:22:38+00:00","breadcrumb":{"@id":"https:\/\/staging.rayzeek.com\/corridor-design-guide#breadcrumb"},"inLanguage":"sv-SE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/staging.rayzeek.com\/corridor-design-guide"]}]},{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/staging.rayzeek.com\/corridor-design-guide#primaryimage","url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg","contentUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/staging.rayzeek.com\/corridor-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/staging.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Corridor Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/staging.rayzeek.com\/#website","url":"https:\/\/staging.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/staging.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/staging.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sv-SE"},{"@type":"Organization","@id":"https:\/\/staging.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/staging.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/staging.rayzeek.com\/sv\/wp-json\/wp\/v2\/pages\/17996","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/staging.rayzeek.com\/sv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/staging.rayzeek.com\/sv\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/sv\/wp-json\/wp\/v2\/comments?post=17996"}],"version-history":[{"count":11,"href":"https:\/\/staging.rayzeek.com\/sv\/wp-json\/wp\/v2\/pages\/17996\/revisions"}],"predecessor-version":[{"id":18158,"href":"https:\/\/staging.rayzeek.com\/sv\/wp-json\/wp\/v2\/pages\/17996\/revisions\/18158"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/sv\/wp-json\/wp\/v2\/media\/17998"}],"wp:attachment":[{"href":"https:\/\/staging.rayzeek.com\/sv\/wp-json\/wp\/v2\/media?parent=17996"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}