RZ038-5A 360-Degree Recessed Ceiling PIR Motion Sensor Switch
RZ038-5A
$15.00
RZ038-5A is a 100-265 VAC recessed ceiling PIR motion sensor switch for automatic lighting control in residential and light commercial rooms.
The 5A model uses live, neutral, and load wiring and provides 360-degree PIR coverage, adjustable time delay, selectable Lux threshold, and high/low sensitivity for ceiling-mounted occupancy control.
- 100-265 VAC line-voltage input, 5A model
- 360-degree PIR detection with 8-12 m detection diameter
- Time delay: 15 s to 30 min
- Lux setting: Off, 15, 25, or 35 Lux
- Neutral wire required for AC wiring
Основные преимущества
- 5A AC model: 100-265 VAC recessed ceiling sensor switch for verified RZ038-5A load ratings.
- Потолочный PIR-обзор: 360-degree detection with 8-12 m detection diameter under manual conditions.
- Installer setup: Push-button settings for time delay, Lux threshold, and high/low sensitivity.
Не нашли то, что искали? Посмотрите наш каталог:
Проконсультироваться со специалистом
Быстрая доставка: 99% в наличии
Полная линейка датчиков движения
Запросить для оптовых заказов ODM/OEM

Recessed 5A Ceiling Control For Everyday Lighting Loads
The RZ038-5A is a recessed ceiling-mounted PIR motion sensor switch for automatic lighting control where a discreet ceiling sensor is preferred over a wall switch.
It connects to 100-265 VAC circuits with live, neutral, and load wiring, giving installers adjustable time delay, Lux level, and sensitivity in a compact spring-clip ceiling form.

Lux Control For Rooms With Changing Daylight
The built-in light sensor can hold lighting off when ambient light is above the selected threshold, helping the sensor respond to motion only when the room needs light.
Use the Off, 15 Lux, 25 Lux, or 35 Lux setting to match bathrooms, utility rooms, hallways, or other indoor areas where daylight and occupancy change during the day.
Характеристики, преимущества, спецификации
The RZ038-5A combines 360-degree PIR detection, 100-265 VAC wiring, and verified 5A load ratings so installers can check coverage, setup, and lighting compatibility before ordering.

Характеристики и преимущества
- 5A line-voltage control: Supports 100-265 VAC lighting circuits with the source-backed RZ038-5A load ratings shown in the specifications.
- PIR-обнаружение 360 градусов: Ceiling placement gives broad room coverage with an 8-12 m detection diameter when installed within the manual conditions.
- Регулируемая задержка времени: Choose 15 s, 30 s, 1 min, 3 min, 5 min, 10 min, or 30 min to match the room traffic pattern.
- Selectable Lux threshold: Set Off, 15 Lux, 25 Lux, or 35 Lux to control whether motion can switch lights on when ambient light is present.
- Высокая/низкая чувствительность: The SENS button lets installers tune detection response for the room layout.
- Spring clip or screw mounting: Mount into an 82-90 mm ceiling cutout or secure to a ceiling/junction box using the documented methods.
- Характеристики
-
Model
RZ038-5A
Тип продукта
Recessed ceiling mount PIR motion sensor switch
Тип датчика
Пассивный инфракрасный (PIR)
Задержка времени
15 s, 30 s, 1 min (default), 3 min, 5 min, 10 min, 30 min
Уровень датчика освещённости
Off, 15 Lux, 25 Lux (default), 35 Lux
Чувствительность
Высокая или Низкая
Power-up behavior
1-minute warm-up after power is turned on or restored
- Electrical
-
Power source
100 VAC ~ 265 VAC
Power frequency
50/60 Hz
Wiring
White to Neutral; Red to Load; Black to Live
Incandescent / Halogen load
500 W / 110 VAC; 1100 W / 220 VAC
Fluorescent / Ballast / LED load
250 W / 110 VAC; 500 W / 220 VAC
- Detection & Installation
-
Диаметр обнаружения
8-12 m when ambient temperature is below 27 C
Дальность обнаружения
360-degree ceiling coverage
Скорость обнаружения движения
0.6-1.5 m/s
Высота установки
2.5-3.5 m
Рабочая температура
-10 to +40 C
Рабочая влажность
< 93% RH
Ceiling cutout
82-90 mm circular hole for spring clip mounting
Face diameter
106 mm
FAQ
Does the RZ038-5A need a neutral wire?
Yes. The AC wiring diagram requires White to Neutral, Red to Load, and Black to Live.
What loads can the 5A model control?
The manual lists 500 W / 110 VAC and 1100 W / 220 VAC for incandescent or halogen loads, and 250 W / 110 VAC and 500 W / 220 VAC for fluorescent, ballast, or LED loads.
Can the sensor keep lights off during bright daylight?
Yes. The Lux button can set Off, 15 Lux, 25 Lux, or 35 Lux, so the light sensor threshold can be matched to the room.
Where should this ceiling sensor be installed?
The manual recommends a 2.5-3.5 m installation height and advises avoiding heat sources, forced air, ventilation systems, ceiling fans, and hanging light fixtures near the sensor.
What happens after power is restored?
The sensor has a 1-minute warm-up period after power-up or power restoration. During that time it will not automatically control the load.
Should I choose the 5A or 10A RZ038 model?
Choose by verified load requirement. The 10A model has higher source-backed load ratings, while the 5A model is for lower-load AC lighting circuits.









Отзывы
Отзывов пока нет.