RZ038-10A 360-Degree Recessed Ceiling PIR Motion Sensor Switch
RZ038-10A
$17.00
RZ038-10A is the higher-load AC version of the recessed ceiling PIR motion sensor switch for automatic lighting control.
It uses the same 360-degree ceiling PIR platform as the 5A model, with 100-265 VAC input, neutral-required AC wiring, and source-backed 10A load ratings for larger compatible lighting loads.
- 100-265 VAC line-voltage input, 10A model
- 360-degree PIR detection with 8-12 m detection diameter
- Time delay: 15 s to 30 min
- Lux setting: Off, 15, 25, or 35 Lux
- Neutral wire required for AC wiring
Основные преимущества
- 10A AC model: 100-265 VAC recessed ceiling sensor switch with higher source-backed load ratings than the 5A model.
- Потолочный PIR-обзор: 360-degree detection with 8-12 m detection diameter under manual conditions.
- Installer setup: Push-button settings for time delay, Lux threshold, and high/low sensitivity.
Не нашли то, что искали? Посмотрите наш каталог:
Проконсультироваться со специалистом
Быстрая доставка: 99% в наличии
Полная линейка датчиков движения
Запросить для оптовых заказов ODM/OEM

Higher-Load AC Ceiling Sensing In A Recessed Form
The RZ038-10A is the higher-load AC model in the recessed RZ038 ceiling sensor family, built for automatic lighting control where a ceiling-mounted PIR switch is the right fit.
It keeps the same compact 360-degree sensing format while using 100-265 VAC live, neutral, and load wiring for projects that need the 10A load-rating profile.

Time Delay Control For Hallways And Shared Rooms
The time-delay button lets installers choose how long the load remains on after the last detected motion, from quick test timing through longer room-occupancy delays.
For hallways, stair areas, storage rooms, and shared indoor spaces, that setting helps the lighting stay on through normal movement and turn off after the area is vacant.
Характеристики, преимущества, спецификации
The RZ038-10A pairs the recessed 360-degree PIR sensing platform with higher verified AC load ratings so installers can compare wiring, timer settings, and load fit.

Характеристики и преимущества
- 10A line-voltage control: Supports 100-265 VAC lighting circuits with the source-backed RZ038-10A load ratings shown in the specifications.
- Higher AC load profile: The 10A model is the RZ038 choice when the verified lighting load exceeds the 5A model rating.
- PIR-обнаружение 360 градусов: Ceiling placement gives broad room coverage with an 8-12 m detection diameter when installed within the manual conditions.
- Регулируемая задержка времени: Choose 15 s, 30 s, 1 min, 3 min, 5 min, 10 min, or 30 min to match the room traffic pattern.
- Selectable Lux threshold: Set Off, 15 Lux, 25 Lux, or 35 Lux to control whether motion can switch lights on when ambient light is present.
- Spring clip or screw mounting: Mount into an 82-90 mm ceiling cutout or secure to a ceiling/junction box using the documented methods.
- Характеристики
-
Model
RZ038-10A
Тип продукта
Recessed ceiling mount PIR motion sensor switch
Тип датчика
Пассивный инфракрасный (PIR)
Задержка времени
15 s, 30 s, 1 min (default), 3 min, 5 min, 10 min, 30 min
Уровень датчика освещённости
Off, 15 Lux, 25 Lux (default), 35 Lux
Чувствительность
Высокая или Низкая
Power-up behavior
1-minute warm-up after power is turned on or restored
- Electrical
-
Power source
100 VAC ~ 265 VAC
Power frequency
50/60 Hz
Wiring
White to Neutral; Red to Load; Black to Live
Incandescent / Halogen load
1000 W / 110 VAC; 2200 W / 220 VAC
Fluorescent / Ballast / LED load
500 W / 110 VAC; 1000 W / 220 VAC
- Detection & Installation
-
Диаметр обнаружения
8-12 m when ambient temperature is below 27 C
Дальность обнаружения
360-degree ceiling coverage
Скорость обнаружения движения
0.6-1.5 m/s
Высота установки
2.5-3.5 m
Рабочая температура
-10 to +40 C
Рабочая влажность
< 93% RH
Ceiling cutout
82-90 mm circular hole for spring clip mounting
Face diameter
106 mm
FAQ
How is the RZ038-10A different from the 5A model?
The 10A model has higher verified AC load ratings. Both use 100-265 VAC input, neutral-required wiring, and the same RZ038 recessed ceiling PIR sensing platform.
Does the RZ038-10A need a neutral wire?
Yes. The AC wiring diagram requires White to Neutral, Red to Load, and Black to Live.
What loads can the 10A model control?
The manual lists 1000 W / 110 VAC and 2200 W / 220 VAC for incandescent or halogen loads, and 500 W / 110 VAC and 1000 W / 220 VAC for fluorescent, ballast, or LED loads.
Can I adjust how long the lights stay on?
Yes. Time delay options are 15 s, 30 s, 1 min, 3 min, 5 min, 10 min, and 30 min.
Can the sensor respond only when the room is dark enough?
Yes. The Lux button supports Off, 15 Lux, 25 Lux, and 35 Lux settings.
What ceiling opening does the spring clip mount need?
The manual lists an 82-90 mm circular ceiling hole for spring clip mounting.









Отзывы