{"id":17981,"date":"2024-05-21T08:20:43","date_gmt":"2024-05-21T08:20:43","guid":{"rendered":"https:\/\/staging.rayzeek.com\/?page_id=17981"},"modified":"2024-06-05T02:22:27","modified_gmt":"2024-06-05T02:22:27","slug":"conference-room-design-guide","status":"publish","type":"page","link":"https:\/\/staging.rayzeek.com\/pt_br\/conference-room-design-guide","title":{"rendered":"Guia de Design de Salas de Reuni\u00e3o"},"content":{"rendered":"<div class=\"wp-block-cover alignfull is-light rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-17983\" alt=\"\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg 1920w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-300x78.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-1024x267.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-768x200.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-1536x400.jpg 1536w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-18x5.jpg 18w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"conference-rooms\">Conference Rooms<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">Discover the energy-saving potential of your conference room with Rayzeek&#8217;s occupancy sensor design guide.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1.jpg\" alt=\"\" class=\"wp-image-17984\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"maximize-energy-efficiency-in-conference-rooms-with-occupancy-sensors\">Maximize Energy Efficiency in Conference Rooms with Occupancy Sensors<\/h2>\n\n<p>Conference rooms are integral to the functioning of any commercial building, serving as the hub for meetings, presentations, and brainstorming sessions. These rooms are often equipped with high-intensity lighting to ensure visibility during presentations and discussions. However, due to their intermittent usage, they are prone to high energy wastage. Lights are often left on when the room is vacant, leading to unnecessary energy consumption.<\/p>\n\n<p>Moreover, the sporadic usage of conference rooms means that they often remain vacant for extended periods, leading to unnecessary energy consumption if the lights are left on. This wastage not only impacts the building&#8217;s energy efficiency but also contributes to higher operational costs.<\/p>\n\n<p>With Rayzeek&#8217;s occupancy sensors, you can transform your conference room into an energy-efficient space, meeting the requirements of energy codes and contributing to a greener environment.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Atenda aos C\u00f3digos de Energia<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>O International Energy Conservation Code (IECC) \u00e9 um c\u00f3digo modelo desenvolvido pelo International Code Council (ICC) para estabelecer requisitos m\u00ednimos de design e constru\u00e7\u00e3o para efici\u00eancia energ\u00e9tica em edif\u00edcios. O IECC \u00e9 atualizado a cada tr\u00eas anos para incorporar as pr\u00e1ticas e tecnologias mais recentes em conserva\u00e7\u00e3o de energia.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC, Por Que Voc\u00ea Deve se Importar<\/h3>\n\n<p>O IECC \u00e9 amplamente adotado por estados e munic\u00edpios nos Estados Unidos. O IECC abrange v\u00e1rios aspectos do uso de energia, incluindo o envelope do edif\u00edcio (paredes, telhados e janelas), sistemas de aquecimento e resfriamento e sistemas de ilumina\u00e7\u00e3o.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>O IECC exige controles de ilumina\u00e7\u00e3o espec\u00edficos, como sensores de ocupa\u00e7\u00e3o, para minimizar o desperd\u00edcio de energia em espa\u00e7os desocupados em v\u00e1rias \u00e1reas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>O ANSI\/ASHRAE\/IES Standard 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, \u00e9 uma norma de energia amplamente reconhecida, publicada pela American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1, Por Que Voc\u00ea Deve se Importar<\/h3>\n\n<p>O ASHRAE 90.1 \u00e9 usado como refer\u00eancia para c\u00f3digos de energia de edif\u00edcios nos Estados Unidos e serve como um caminho de conformidade dentro do IECC, que descreve requisitos m\u00ednimos para o desempenho energ\u00e9tico eficiente dos componentes de edif\u00edcios comerciais, incluindo envelopes de edif\u00edcios, sistemas de HVAC, sistemas de aquecimento de \u00e1gua e sistemas de ilumina\u00e7\u00e3o. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>O padr\u00e3o ASHRAE 90.1 especifica densidades de pot\u00eancia de ilumina\u00e7\u00e3o m\u00e1ximas permitidas e requisitos m\u00ednimos de controle de ilumina\u00e7\u00e3o, incluindo o uso de sensores de ocupa\u00e7\u00e3o em \u00e1reas espec\u00edficas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>Title 24, parte 6 do California Building Standards Code, oficialmente conhecido como Building Energy Efficiency Standards for Residential and Nonresidential Buildings, o Title 24 \u00e9 administrado pela California Energy Commission e \u00e9 atualizado periodicamente para refletir novas tecnologias e m\u00e9todos de efici\u00eancia energ\u00e9tica.<\/p>\n\n<h3 class=\"wp-block-heading\">Title 24, Por Que Voc\u00ea Deve se Importar<\/h3>\n\n<p>O Title 24 \u00e9 conhecido por seus requisitos rigorosos, frequentemente considerados mais rigorosos do que os encontrados em muitos outros c\u00f3digos de energia nos Estados Unidos. O Title 24 exige padr\u00f5es rigorosos de desempenho energ\u00e9tico para todos os aspectos da constru\u00e7\u00e3o de edif\u00edcios, o que inclui aquecimento, ventila\u00e7\u00e3o, ar condicionado (HVAC), aquecimento de \u00e1gua e ilumina\u00e7\u00e3o.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>O Title 24 exige a instala\u00e7\u00e3o de sensores de ocupa\u00e7\u00e3o que ajustam a ilumina\u00e7\u00e3o com base na ocupa\u00e7\u00e3o da sala em \u00e1reas espec\u00edficas de edif\u00edcios comerciais para garantir que a energia n\u00e3o seja desperdi\u00e7ada.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Ado\u00e7\u00e3o do C\u00f3digo de Energia por Estado<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">Expandir para ver a tabela detalhada \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Estado<\/th><th>C\u00f3digo Comercial Atual<\/th><th>Categoria de Efici\u00eancia do C\u00f3digo Comercial<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alasca<\/td><td>Nenhum estadual<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Arizona<\/td><td>Regra local<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>2009 IECC e 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Calif\u00f3rnia<\/td><td>2022 Building Energy Efficiency Standards<\/td><td>90.1-2019<\/td><\/tr><tr><td>Colorado<\/td><td>Regra local<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Connecticut<\/td><td>2021 IECC e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>2018 IECC e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Distrito de Columbia<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Fl\u00f3rida<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Ge\u00f3rgia<\/td><td>2015 IECC e 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Hava\u00ed<\/td><td>Regra local<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>2018 IECC e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>2021 IECC e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Regra local<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Kentucky<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Louisiana<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Michigan<\/td><td>2015 IECC e 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Mississippi<\/td><td>Nenhum estadual<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Missouri<\/td><td>Regra local<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Montana<\/td><td>2021 IECC e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>2018 IECC e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>2018 IECC e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Hampshire<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>New Mexico<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>New York<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>North Carolina<\/td><td>2015 IECC e 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>North Dakota<\/td><td>Regra local<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Ohio<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>IECC 2006 e 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oregon<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pennsylvania<\/td><td>2018 IECC e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>South Carolina<\/td><td>2009 IECC e 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>South Dakota<\/td><td>Regra local<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2021 e 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>C\u00f3digo de Energia do Estado de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>C\u00f3digo de Energia do Estado de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>West Virginia<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>2015 IECC e 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Regra local<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ Quando uma emenda que impacta a efici\u00eancia energ\u00e9tica pode ser quantificada usando os Modelos de Edifica\u00e7\u00e3o Prot\u00f3tipo do DOE, ela foi inclu\u00edda na an\u00e1lise.<\/li>\n\n<li>Para estados que adotam tanto o IECC quanto o 90.1, o c\u00f3digo IECC \u00e9 geralmente analisado como o c\u00f3digo atual do estado neste estudo, exceto para estados com emendas extensivas ao IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Solu\u00e7\u00f5es com Sensores<\/h4>\n\n<p>Descubra como a Rayzeek pode resolver seus desafios de economia de energia.<\/p>\n\n<a  href=\"https:\/\/staging.rayzeek.com\/pt_br\/produtos\"><div class=\"offering_button\"><p>Ver Todas as Ofertas<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-conference-rooms\">Design Guide Key Concepts for Conference Rooms<\/h2>\n\n<p>Designing an energy-efficient lighting control solution for conference rooms involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3.jpg\" alt=\"\" class=\"wp-image-17986\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>Designing an energy-efficient lighting system for a conference room involves strategic placement of occupancy sensors to ensure comprehensive coverage. Here are some guidelines to consider:<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>Entrance Coverage<\/strong>: Install a wall-mounted sensor near the entrance to detect when someone enters or exits the room. This sensor should be positioned high enough to avoid obstruction from the open door and should not directly face the entrance to avoid false triggers from movement outside the room.<\/li>\n\n<li><strong>Table Coverage<\/strong>: Place a ceiling-mounted sensor above the conference table to detect occupancy in the main area of the room. This sensor should be positioned centrally to ensure comprehensive coverage.<\/li>\n\n<li><strong>Presentation Area Coverage<\/strong>: If your conference room has a dedicated presentation area, consider installing an additional wall-mounted sensor to cover this space. This sensor should be positioned to avoid any potential obstructions, such as screens or projectors.<\/li>\n\n<li><strong>Wall Control<\/strong>: Install a wall control unit near the entrance for manual override or adjustments of the lighting settings. This control should be easily accessible upon entering or exiting the room.<\/li>\n\n<li><strong>Avoidance of Obstructions and Interference<\/strong>: Ensure that sensors are not placed near air vents to prevent interference from air flow or vibrations. Also, consider the height and placement of furniture to avoid blocking the sensor&#8217;s field of view.<\/li>\n\n<li><strong>Integration with Existing Systems<\/strong>: Our occupancy sensors can be integrated with existing lighting systems for seamless operation. They can also be programmed to turn off all lights after a certain period of inactivity, further enhancing energy efficiency.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Produtos e Solu\u00e7\u00f5es em Destaque<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/staging.rayzeek.com\/pt_br\/categoria-produto\/sensores-de-movimento\/wall-mount-motion-sensors\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Interruptores com Sensor de Parede<\/h3>\n\n<h4 class=\"wp-block-heading\">Interruptores com Sensor de Movimento RZ020\/021<\/h4>\n\n<ul class=\"wp-block-list\"><li>Op\u00e7\u00f5es de fia\u00e7\u00e3o 2 fios, 3 fios, 4 fios <\/li>\n\n<li>Ocupa\u00e7\u00e3o, Vac\u00e2ncia, Manual ON\/OFF<\/li>\n\n<li>Tempo de atraso ajust\u00e1vel e controle de luz ambiente<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/staging.rayzeek.com\/pt_br\/categoria-produto\/sensores-de-movimento-sem-fio\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensores de Parede Sem Fio Multi-local<\/h3>\n\n<h4 class=\"wp-block-heading\">Kits RZ020A\/021A + RZ022W<\/h4>\n\n<ul class=\"wp-block-list\"><li>Interruptor com sensor de ocupa\u00e7\u00e3o cabeado RZ021A\/022A<\/li>\n\n<li>Interruptor complementar sem fio (RZ022W) para controle multi-local<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/staging.rayzeek.com\/pt_br\/categoria-produto\/sensores-de-ocupacao\/montagem-no-teto\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensores de Ocupa\u00e7\u00e3o de Teto<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>Sensores de ocupa\u00e7\u00e3o cabeados<\/li>\n\n<li>Auto ON, auto OFF <\/li>\n\n<li>Tens\u00e3o de linha e baixa tens\u00e3o dispon\u00edveis<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Recursos principais inclu\u00eddos:<\/h3>\n\n<ul class=\"wp-block-list\"><li>Controle manual integrado ON\/OFF para todas as ilumina\u00e7\u00f5es<\/li>\n\n<li>Sensores de vac\u00e2ncia (somente Manual ON): As luzes devem ser ligadas manualmente<\/li>\n\n<li>Tempo de atraso ajust\u00e1vel, a ilumina\u00e7\u00e3o \u00e9 automaticamente desligada completamente ap\u00f3s 15 minutos<\/li>\n\n<li>Adicional: kits sem fio multi-local para expandir o alcance de controle sem re-fia\u00e7\u00e3o<\/li>\n\n<li>Adicional: m\u00faltiplas op\u00e7\u00f5es de fia\u00e7\u00e3o dispon\u00edveis tanto para novas constru\u00e7\u00f5es quanto para projetos de retrofit.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4.jpg\" alt=\"\" class=\"wp-image-17982\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Atende \u00e0s Disposi\u00e7\u00f5es Obrigat\u00f3rias<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC \u2013 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Controles de sensor de ocupante<\/h4>\n\n<p>Os controles de sensor de ocupante devem ser instalados para controlar as ilumina\u00e7\u00f5es no espa\u00e7o.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Fun\u00e7\u00f5es do controle de sensor de ocupante<\/h4>\n\n<ul class=\"wp-block-list\"><li>Liga\u00e7\u00e3o manual ou parcial com no m\u00e1ximo 50% de pot\u00eancia.<\/li>\n\n<li>Desligamento completo dentro de 20 minutos ap\u00f3s todos os ocupantes terem deixado o espa\u00e7o<\/li>\n\n<li>Um controle manual para desligar as luzes.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"9411-a-local-control\">9.4.1.1 a Controle local<\/h4>\n\n<p>Deve haver um ou mais dispositivos de controle de ilumina\u00e7\u00e3o manual que forne\u00e7am controle LIGAR e DESLIGAR<br>de todas as ilumina\u00e7\u00f5es no espa\u00e7o.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-b-restricted-to-manual-on\">9.4.1.1 b Restrito a LIGAR manualmente<\/h4>\n\n<p>Nenhuma das ilumina\u00e7\u00f5es deve ser ligada automaticamente<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-c-restricted-to-partial-automatic-on\">9.4.1.1 c Restricted to partial automatic ON<\/h4>\n\n<p>No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on<\/p>\n\n<p>** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 h Automatic full OFF control <\/h4>\n\n<p>Todas as ilumina\u00e7\u00f5es no espa\u00e7o devem ser automaticamente desligadas dentro de 20 minutos de todos os ocupantes terem deixado o espa\u00e7o<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">Title 24 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) Controles manuais de \u00e1rea.<\/h4>\n\n<p>Cada \u00e1rea delimitada por divis\u00f3rias de altura do teto deve dispor de controles de ilumina\u00e7\u00e3o que permitam o acionamento e desligamento manual da ilumina\u00e7\u00e3o naquela \u00e1rea.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Controles de desligamento.<\/h4>\n\n<p>A ilumina\u00e7\u00e3o deve ser controlada com controles de detec\u00e7\u00e3o de ocupa\u00e7\u00e3o para desligar automaticamente toda a ilumina\u00e7\u00e3o em 20 minutos ou menos ap\u00f3s a zona de controle ficar desocupada, devendo funcionar como:<\/p>\n\n<ul class=\"wp-block-list\"><li>A. Controles de detec\u00e7\u00e3o de ocupa\u00e7\u00e3o (se 130.1(b) n\u00e3o exigir controles de ilumina\u00e7\u00e3o multin\u00edvel); ou<\/li>\n\n<li>B. Controles de detec\u00e7\u00e3o de ocupa\u00e7\u00e3o parcial (partial-ON), ou<\/li>\n\n<li>C. Controles de detec\u00e7\u00e3o de vac\u00e2ncia, onde toda a ilumina\u00e7\u00e3o responde apenas a uma entrada manual de LIGAR.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Deixe-nos ouvir voc\u00ea.<\/h3>\n\n<p>Deixe a Rayzeek ajudar a projetar e entregar uma solu\u00e7\u00e3o de ilumina\u00e7\u00e3o personalizada de economia de energia para voc\u00ea.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/pt_br\/wp-json\/wp\/v2\/pages\/17981#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Formul\u00e1rio de contato\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/pt_br\/wp-json\/wp\/v2\/pages\/17981#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Enviar\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"pt_br\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Conference rooms are integral to the functioning of any commercial building, serving as the hub for meetings, presentations, and brainstorming sessions.<\/p>","protected":false},"author":1,"featured_media":17983,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-17981","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Conference Room Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/staging.rayzeek.com\/pt_br\/conference-room-design-guide\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Conference Room Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"Conference rooms are integral to the functioning of any commercial building, serving as the hub for meetings, presentations, and brainstorming sessions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/staging.rayzeek.com\/pt_br\/conference-room-design-guide\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide\",\"url\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide\",\"name\":\"Conference Room Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T08:20:43+00:00\",\"dateModified\":\"2024-06-05T02:22:27+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/staging.rayzeek.com\/conference-room-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide#primaryimage\",\"url\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/staging.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Conference Room Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/staging.rayzeek.com\/#website\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/staging.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Conference Room Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/staging.rayzeek.com\/pt_br\/conference-room-design-guide","og_locale":"pt_BR","og_type":"article","og_title":"Conference Room Energy Code Design Guide - Rayzeek","og_description":"Conference rooms are integral to the functioning of any commercial building, serving as the hub for meetings, presentations, and brainstorming sessions.","og_url":"https:\/\/staging.rayzeek.com\/pt_br\/conference-room-design-guide","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:27+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Est. tempo de leitura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/staging.rayzeek.com\/conference-room-design-guide","url":"https:\/\/staging.rayzeek.com\/conference-room-design-guide","name":"Conference Room Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/staging.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/staging.rayzeek.com\/conference-room-design-guide#primaryimage"},"image":{"@id":"https:\/\/staging.rayzeek.com\/conference-room-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg","datePublished":"2024-05-21T08:20:43+00:00","dateModified":"2024-06-05T02:22:27+00:00","breadcrumb":{"@id":"https:\/\/staging.rayzeek.com\/conference-room-design-guide#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/staging.rayzeek.com\/conference-room-design-guide"]}]},{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/staging.rayzeek.com\/conference-room-design-guide#primaryimage","url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg","contentUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/staging.rayzeek.com\/conference-room-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/staging.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Conference Room Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/staging.rayzeek.com\/#website","url":"https:\/\/staging.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/staging.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/staging.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Organization","@id":"https:\/\/staging.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/staging.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/staging.rayzeek.com\/pt_br\/wp-json\/wp\/v2\/pages\/17981","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/staging.rayzeek.com\/pt_br\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/staging.rayzeek.com\/pt_br\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/pt_br\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/pt_br\/wp-json\/wp\/v2\/comments?post=17981"}],"version-history":[{"count":7,"href":"https:\/\/staging.rayzeek.com\/pt_br\/wp-json\/wp\/v2\/pages\/17981\/revisions"}],"predecessor-version":[{"id":18159,"href":"https:\/\/staging.rayzeek.com\/pt_br\/wp-json\/wp\/v2\/pages\/17981\/revisions\/18159"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/pt_br\/wp-json\/wp\/v2\/media\/17983"}],"wp:attachment":[{"href":"https:\/\/staging.rayzeek.com\/pt_br\/wp-json\/wp\/v2\/media?parent=17981"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}