{"id":20169,"date":"2026-06-05T03:13:44","date_gmt":"2026-06-05T03:13:44","guid":{"rendered":"https:\/\/staging.rayzeek.com\/?post_type=product&#038;p=20169"},"modified":"2026-06-05T03:13:44","modified_gmt":"2026-06-05T03:13:44","slug":"rz037-dry","status":"publish","type":"product","link":"https:\/\/staging.rayzeek.com\/pt\/produtos\/rz037-contacto-seco\/","title":{"rendered":"Sensor de ocupa\u00e7\u00e3o PIR de montagem no teto RZ037-DRY com rel\u00e9 de contacto seco"},"content":{"rendered":"<div class=\"wp-block-group rz_product_two_col_group col_img_right\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view-1024x1024.jpg\" alt=\"Vista frontal do sensor de ocupa\u00e7\u00e3o PIR de montagem no teto RZ037\" class=\"wp-image-19335\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view.jpg 1080w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"drycontact-occupancy-sensing-for-control-systems\">Dete\u00e7\u00e3o de ocupa\u00e7\u00e3o por contacto seco para sistemas de controlo<\/h2>\n\n<p>O RZ037-DRY adapta o formato do sensor PIR de teto RZ037 para sistemas de controlo de baixa tens\u00e3o que necessitam de um sinal de ocupa\u00e7\u00e3o em vez de uma carga de ilumina\u00e7\u00e3o comutada diretamente.<\/p>\n\n<p>O seu rel\u00e9 isolado fornece contactos Comum, Normalmente Aberto e Normalmente Fechado, tornando-o adequado para entradas de EMS, AVAC e controlo de edif\u00edcios onde o controlador decide que a\u00e7\u00e3o se segue \u00e0 dete\u00e7\u00e3o de ocupa\u00e7\u00e3o.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rz_product_two_col_group col_img_left\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-commercial-hvac-context-1024x1024.jpg\" alt=\"Condutas de AVAC de teto para salas de confer\u00eancia comerciais para o contexto de controlo de ocupa\u00e7\u00e3o por contacto seco RZ037-DRY\" class=\"wp-image-20167\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-commercial-hvac-context-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-commercial-hvac-context-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-commercial-hvac-context-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-commercial-hvac-context-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-commercial-hvac-context-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-commercial-hvac-context-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-commercial-hvac-context.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"connect-occupancy-sensing-to-building-controls\">Ligar a dete\u00e7\u00e3o de ocupa\u00e7\u00e3o aos controlos do edif\u00edcio<\/h2>\n\n<p>Utilize a sa\u00edda de contacto seco quando um painel de controlo, controlador de AVAC ou entrada de gest\u00e3o de energia necessitar de saber se um espa\u00e7o est\u00e1 ocupado sem colocar o sensor no circuito de carga principal.<\/p>\n\n<p>Os instaladores podem escolher a l\u00f3gica de contacto NO ou NC de acordo com o sistema recetor e, em seguida, sintonizar o atraso de tempo, o n\u00edvel de Lux e a sensibilidade PIR a partir do corpo do sensor ap\u00f3s a cablagem.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rz_product_center_h2_underline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2>Caracter\u00edsticas, Benef\u00edcios, Especifica\u00e7\u00f5es<\/h2>\n\n<p>O RZ037-DRY combina dete\u00e7\u00e3o de ocupa\u00e7\u00e3o PIR de teto, alimenta\u00e7\u00e3o de 12\/24V AC\/DC e contactos COM\/NO\/NC isolados para que os instaladores possam verificar a cobertura, a l\u00f3gica do rel\u00e9 e os valores de configura\u00e7\u00e3o antes de encomendar.<\/p><\/div><\/div><div class=\"wp-block-group rz_product_two_col_group col_img_left\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-spec.jpg\" alt=\"Imagem da especifica\u00e7\u00e3o e do esquema de liga\u00e7\u00e3o do contacto seco RZ037-DRY\" class=\"wp-image-20168\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-spec.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-spec-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-spec-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-spec-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-spec-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2026\/06\/rz037-dry-spec-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group rz_sec_feature_txt\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"features-amp-benefits\">Caracter\u00edsticas e Benef\u00edcios<\/h2>\n\n<ul class=\"wp-block-list\"><li><strong>Rel\u00e9 de contacto seco isolado:<\/strong> As sa\u00eddas COM, NO e NC suportam entradas de sistemas de controlo em vez de comuta\u00e7\u00e3o direta de carga de tens\u00e3o de rede.<\/li>\n\n<li><strong>Alimenta\u00e7\u00e3o 12\/24V AC\/DC:<\/strong> O sensor pode ser alimentado a partir de energia de controlo de baixa tens\u00e3o de 12\/24VDC ou 12\/24VAC.<\/li>\n\n<li><strong>Dete\u00e7\u00e3o PIR de 360 graus:<\/strong> A dete\u00e7\u00e3o por infravermelhos passivos montada no teto cobre a ocupa\u00e7\u00e3o em redor da posi\u00e7\u00e3o do sensor.<\/li>\n\n<li><strong>Atraso de tempo ajust\u00e1vel:<\/strong> Selecione de 15 segundos a 30 minutos para corresponder ao comportamento em testes, passagens, casas de banho ou \u00e1reas de trabalho.<\/li>\n\n<li><strong>Controlo de Lux selecion\u00e1vel:<\/strong> As defini\u00e7\u00f5es Desligado, 15 Lux, 25 Lux e 35 Lux permitem aos instaladores decidir quando \u00e9 que a luz ambiente deve manter o rel\u00e9 desligado.<\/li>\n\n<li><strong>Sensibilidade alta\/baixa:<\/strong> O sensor pode ser ajustado para o padr\u00e3o de movimento esperado e para as condi\u00e7\u00f5es da divis\u00e3o.<\/li>\n\n<li><strong>Identifica\u00e7\u00e3o clara dos fios:<\/strong> O vermelho e o preto fornecem a alimenta\u00e7\u00e3o de entrada, enquanto o verde, o laranja e o amarelo fornecem a cablagem do rel\u00e9 NC, COM e NO.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rz_product_specfication\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><dl>\n<dt>Caracter\u00edsticas<\/dt>\n<dd>\n<p>Tipo de produto<\/p>\n<p>Sensor de ocupa\u00e7\u00e3o PIR de montagem no teto com sa\u00edda de rel\u00e9 de contacto seco<\/p>\n<p>Tens\u00e3o de entrada<\/p>\n<p>12\/24VDC ou 12\/24VAC<\/p>\n<p>Contactos do rel\u00e9<\/p>\n<p>Normalmente Fechado (NC), Comum (COM), Normalmente Aberto (NO)<\/p>\n<p>Capacidade do rel\u00e9<\/p>\n<p>Entrada COM 30VDC m\u00e1x; sa\u00edda NC\/NO 1A m\u00e1x<\/p>\n<p>Fios do cabo<\/p>\n<p>Vermelho IN+, Verde NC, Laranja COM, Amarelo NO, Preto IN-<\/p>\n<p>Tipo de sensor<\/p>\n<p>Infravermelho passivo (PIR)<\/p>\n<p>Alcance de dete\u00e7\u00e3o<\/p>\n<p>360 graus<\/p>\n<p>Di\u00e2metro de dete\u00e7\u00e3o<\/p>\n<p>8-12m quando a temperatura ambiente \u00e9 inferior a 27C<\/p>\n<p>Velocidade de dete\u00e7\u00e3o de movimento<\/p>\n<p>0.6-1.5m\/s<\/p>\n<p>Altura de instala\u00e7\u00e3o<\/p>\n<p>2.5-3.5m<\/p>\n<p>Temporiza\u00e7\u00e3o<\/p>\n<p>15s, 30s, 1min predefinido, 3min, 5min, 10min, 30min<\/p>\n<p>N\u00edvel do sensor de luz<\/p>\n<p>Desligado, 15Lux, 25Lux predefinido, 35Lux<\/p>\n<p>Sensibilidade<\/p>\n<p>Alta ou Baixa<\/p>\n<p>Temperatura de funcionamento<\/p>\n<p>-10 a +40C<\/p>\n<p>Humidade de funcionamento<\/p>\n<p>&lt;93% RH<\/p>\n<\/dd>\n<\/dl><\/div><\/div><div class=\"wp-block-group rz_product_h2 rz_product_width\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading rz_prod_video_heading\" id=\"faq\">FAQ<\/h2><\/div><\/div><div class=\"wp-block-group ast_woo_outer_group_large\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group ast_woo_faqs\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"h-what-makes-rz037-dry-different-from-the-line-voltage-rz037-models\">O que diferencia o RZ037-DRY dos modelos RZ037 de tens\u00e3o de rede?<\/h3><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>O RZ037-DRY fornece uma sa\u00edda de rel\u00e9 de contacto seco isolado para uma entrada de sistema de controlo. N\u00e3o est\u00e1 especificado como um interruptor direto de carga de ilumina\u00e7\u00e3o de tens\u00e3o de rede como as variantes RZ037 de alta tens\u00e3o.<\/p><\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"h-what-power-supply-does-rz037-dry-need\">De que fonte de alimenta\u00e7\u00e3o necessita o RZ037-DRY?<\/h3><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>O manual especifica uma pot\u00eancia de entrada de 12\/24VDC ou 12\/24VAC. O vermelho \u00e9 IN+ e o preto \u00e9 IN- no esquema de cablagem fornecido.<\/p><\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"h-which-dry-contact-wires-are-available\">Quais s\u00e3o os fios de contacto seco dispon\u00edveis?<\/h3><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>A sa\u00edda do rel\u00e9 fornece verde para Normalmente Fechado, laranja para Comum e amarelo para Normalmente Aberto. Escolha a l\u00f3gica NO ou NC de acordo com a entrada de rece\u00e7\u00e3o do EMS, HVAC ou controlo do edif\u00edcio.<\/p><\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"h-can-this-sensor-be-used-with-ems-or-hvac-systems\">Este sensor pode ser utilizado com sistemas EMS ou HVAC?<\/h3><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>Sim. A descri\u00e7\u00e3o do produto no manual identifica os sistemas EMS e HVAC como integra\u00e7\u00f5es-alvo, sendo a ocupa\u00e7\u00e3o comunicada atrav\u00e9s do contacto seco do rel\u00e9 isolado interno.<\/p><\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"h-what-coverage-should-installers-expect\">Que cobertura devem os instaladores esperar?<\/h3><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>O manual especifica uma dete\u00e7\u00e3o de 360 graus com um di\u00e2metro de dete\u00e7\u00e3o de 8-12m quando a temperatura ambiente est\u00e1 abaixo de 27C, e uma altura de instala\u00e7\u00e3o recomendada de 2,5-3,5m.<\/p><\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"h-which-setup-values-can-be-adjusted\">Quais s\u00e3o os valores de configura\u00e7\u00e3o que podem ser ajustados?<\/h3><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>Os instaladores podem ajustar o atraso de tempo, o n\u00edvel do sensor de luz e a sensibilidade. As op\u00e7\u00f5es de atraso de tempo variam entre 15 segundos e 30 minutos, as op\u00e7\u00f5es de Lux incluem Desligado, 15Lux, 25Lux e 35Lux, e a sensibilidade pode ser definida para Alta ou Baixa.<\/p><\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"h-why-might-the-sensor-not-trigger-immediately-after-power-is-restored\">Porque \u00e9 que o sensor pode n\u00e3o ser acionado imediatamente ap\u00f3s a reposi\u00e7\u00e3o da energia?<\/h3><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>O manual refere que, quando a energia \u00e9 ligada ou reposta pela primeira vez, o sensor n\u00e3o controlar\u00e1 automaticamente a carga durante o primeiro minuto.<\/p><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><script>\nvar headers = document.querySelectorAll('.ast_woo_faqs > div > div > div > div:first-child');\nfor (var i = 0; i < headers.length; i++) {\n    headers[i].addEventListener('click', openAccordion);\n}\n\nfunction openAccordion(e) {\n    var parent = this.parentElement.parentElement;\n    var article = this.nextElementSibling;\n\n    if (!parent.classList.contains('open')) {\n        parent.classList.add('open');\n        article.style.maxHeight = article.scrollHeight + 'px';\n    } else {\n        parent.classList.remove('open');\n        article.style.maxHeight = '0px';\n    }\n}\n\nfunction appenddiv() {\n    var elements = document.querySelectorAll('.ast_woo_faqs > div > div > div > div:first-child > .wp-block-group__inner-container');\n\n    for (var k in elements) {\n        var div1 = document.createElement('div');\n        div1.className = 'ast_woo_icon';\n        elements[k].appendChild(div1);\n    }\n}\nappenddiv();\n<\/script><div class=\"wp-block-group rz_product_contact_banner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2021\/05\/rz022-occupancy-sensor-c2a-links.jpg\" alt=\"Sensor de ocupa\u00e7\u00e3o EU rz022 c2a\"\/><\/figure>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"expand-your-motion-sensors\">Expanda os Seus Sensores de Movimento<br><\/h2>\n\n<p>Ver todos os nossos produtos economizadores de energia em sensores de movimento<a href=\"https:\/\/staging.rayzeek.com\/pt\/produtos\/rz021-5a-n\/\"><\/a><\/p>\n\n<div><a href=\"https:\/\/staging.rayzeek.com\/pt\/motion-sensor\/\"><div class=\"button-wrapper\"><div>Sensores de Movimento<\/div><\/div><\/a><a href=\"https:\/\/staging.rayzeek.com\/pt\/motion-sensor-switches\/\"><div class=\"button-wrapper\"><div>Interruptores com Sensor de Movimento<\/div><\/div><\/a><a href=\"https:\/\/staging.rayzeek.com\/pt\/occupancy-vacancy-sensors\/\"><div class=\"button-wrapper\"><div>Sensores de Ocupa\u00e7\u00e3o<\/div><\/div><\/a><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<div id=\"product_sd_main\" class=\"hide\">\n<p>O RZ037-DRY \u00e9 um sensor de ocupa\u00e7\u00e3o PIR para montagem no teto com uma sa\u00edda de rel\u00e9 de contacto seco isolado para entradas de EMS, AVAC e controlo de edif\u00edcios.<\/p>\n<div>\n<p>Aceita alimenta\u00e7\u00e3o de 12\/24VDC ou 12\/24VAC e fornece contactos de rel\u00e9 COM, NO e NC para que um sistema de controlo possa receber o estado de ocupa\u00e7\u00e3o sem que o sensor comute diretamente cargas de tens\u00e3o de rede.<\/p>\n<ul>\n<li>Sa\u00edda de rel\u00e9 de contacto seco isolado com contactos COM, NO e NC<\/li>\n<li>Contactos de rel\u00e9 nominais para 30VDC m\u00e1x. e 1A m\u00e1x.<\/li>\n<li>Dete\u00e7\u00e3o de ocupa\u00e7\u00e3o PIR de 360 graus a partir de uma posi\u00e7\u00e3o no teto<\/li>\n<li>Atraso de tempo, n\u00edvel de Lux e sensibilidade alta\/baixa ajust\u00e1veis<\/li>\n<li>Concebido para cablagem de sistemas de controlo de baixa tens\u00e3o, n\u00e3o para comuta\u00e7\u00e3o de cargas de alta tens\u00e3o<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"product_sd_main_read\">Ler mais<\/div>","protected":false},"featured_media":19335,"comment_status":"open","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":""},"product_brand":[],"product_cat":[152,77,150,55,89],"product_tag":[153],"class_list":{"0":"post-20169","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ceiling-mount-motion-sensors","7":"product_cat-ceiling-mount","8":"product_cat-low-voltage-motion-sensors","9":"product_cat-motion-sensors","10":"product_cat-occupancy-sensors","11":"product_tag-noele","12":"sales-flash-overlay","13":"woocommerce-text-align-left","14":"woocommerce-image-align-center","15":"do-quantity-buttons","17":"first","18":"instock","19":"shipping-taxable","20":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>RZ037-DRY Dry Contact PIR Occupancy Sensor | Rayzeek<\/title>\n<meta name=\"description\" content=\"RZ037-DRY ceiling mount PIR occupancy sensor with isolated dry-contact COM, NO, and NC relay output for EMS, HVAC, and building control systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/staging.rayzeek.com\/pt\/produtos\/rz037-contacto-seco\/\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RZ037-DRY Dry Contact PIR Occupancy Sensor | Rayzeek\" \/>\n<meta property=\"og:description\" content=\"RZ037-DRY ceiling mount PIR occupancy sensor with isolated dry-contact COM, NO, and NC relay output for EMS, HVAC, and building control systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/staging.rayzeek.com\/pt\/produtos\/rz037-contacto-seco\/\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"og:image\" content=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":[\"WebPage\",\"ItemPage\"],\"@id\":\"https:\/\/staging.rayzeek.com\/products\/rz037-dry\",\"url\":\"https:\/\/staging.rayzeek.com\/products\/rz037-dry\",\"name\":\"RZ037-DRY Dry Contact PIR Occupancy Sensor | Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/staging.rayzeek.com\/products\/rz037-dry#primaryimage\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/products\/rz037-dry#primaryimage\"},\"thumbnailUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view.jpg\",\"datePublished\":\"2026-06-05T03:13:44+00:00\",\"description\":\"RZ037-DRY ceiling mount PIR occupancy sensor with isolated dry-contact COM, NO, and NC relay output for EMS, HVAC, and building control systems.\",\"breadcrumb\":{\"@id\":\"https:\/\/staging.rayzeek.com\/products\/rz037-dry#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/staging.rayzeek.com\/products\/rz037-dry\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/staging.rayzeek.com\/products\/rz037-dry#primaryimage\",\"url\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view.jpg\",\"contentUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view.jpg\",\"width\":1080,\"height\":1080},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/staging.rayzeek.com\/products\/rz037-dry#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/staging.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/staging.rayzeek.com\/id\/produk-2\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"RZ037-DRY Ceiling Mount PIR Occupancy Sensor with Dry Contact Relay\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/staging.rayzeek.com\/#website\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/staging.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"RZ037-DRY Dry Contact PIR Occupancy Sensor | Rayzeek","description":"RZ037-DRY ceiling mount PIR occupancy sensor with isolated dry-contact COM, NO, and NC relay output for EMS, HVAC, and building control systems.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/staging.rayzeek.com\/pt\/produtos\/rz037-contacto-seco\/","og_locale":"pt_PT","og_type":"article","og_title":"RZ037-DRY Dry Contact PIR Occupancy Sensor | Rayzeek","og_description":"RZ037-DRY ceiling mount PIR occupancy sensor with isolated dry-contact COM, NO, and NC relay output for EMS, HVAC, and building control systems.","og_url":"https:\/\/staging.rayzeek.com\/pt\/produtos\/rz037-contacto-seco\/","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","og_image":[{"width":1080,"height":1080,"url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Tempo estimado de leitura":"3 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["WebPage","ItemPage"],"@id":"https:\/\/staging.rayzeek.com\/products\/rz037-dry","url":"https:\/\/staging.rayzeek.com\/products\/rz037-dry","name":"RZ037-DRY Dry Contact PIR Occupancy Sensor | Rayzeek","isPartOf":{"@id":"https:\/\/staging.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/staging.rayzeek.com\/products\/rz037-dry#primaryimage"},"image":{"@id":"https:\/\/staging.rayzeek.com\/products\/rz037-dry#primaryimage"},"thumbnailUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view.jpg","datePublished":"2026-06-05T03:13:44+00:00","description":"RZ037-DRY ceiling mount PIR occupancy sensor with isolated dry-contact COM, NO, and NC relay output for EMS, HVAC, and building control systems.","breadcrumb":{"@id":"https:\/\/staging.rayzeek.com\/products\/rz037-dry#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/staging.rayzeek.com\/products\/rz037-dry"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/staging.rayzeek.com\/products\/rz037-dry#primaryimage","url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view.jpg","contentUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2025\/11\/rz037-front-view.jpg","width":1080,"height":1080},{"@type":"BreadcrumbList","@id":"https:\/\/staging.rayzeek.com\/products\/rz037-dry#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/staging.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/staging.rayzeek.com\/id\/produk-2\/"},{"@type":"ListItem","position":3,"name":"RZ037-DRY Ceiling Mount PIR Occupancy Sensor with Dry Contact Relay"}]},{"@type":"WebSite","@id":"https:\/\/staging.rayzeek.com\/#website","url":"https:\/\/staging.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/staging.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/staging.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"},{"@type":"Organization","@id":"https:\/\/staging.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/staging.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/product\/20169","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/comments?post=20169"}],"version-history":[{"count":1,"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/product\/20169\/revisions"}],"predecessor-version":[{"id":20178,"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/product\/20169\/revisions\/20178"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/media\/19335"}],"wp:attachment":[{"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/media?parent=20169"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/product_brand?post=20169"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/product_cat?post=20169"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/product_tag?post=20169"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}