{"id":17996,"date":"2024-05-21T08:41:22","date_gmt":"2024-05-21T08:41:22","guid":{"rendered":"https:\/\/staging.rayzeek.com\/?page_id=17996"},"modified":"2024-06-05T02:22:38","modified_gmt":"2024-06-05T02:22:38","slug":"corridor-design-guide","status":"publish","type":"page","link":"https:\/\/staging.rayzeek.com\/pt\/corridor-design-guide","title":{"rendered":"Guia de Design de Corredores"},"content":{"rendered":"<div class=\"wp-block-cover alignfull is-light rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-17998\" alt=\"\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg 1920w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-300x78.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-1024x267.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-768x200.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-1536x400.jpg 1536w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-18x5.jpg 18w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"corridors\">Corridors<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">Discover the energy-saving potential of corridors with Rayzeek&#8217;s occupancy sensor design guide. Uncover the power of automated lighting control in your commercial building&#8217;s passageways.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4.jpg\" alt=\"\" class=\"wp-image-17997\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"lighting-the-way-to-energy-efficiency-in-corridors\">Lighting the Way to Energy Efficiency in Corridors<\/h2>\n\n<p>Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption. These spaces typically use fluorescent or LED lighting, which, while energy-efficient, can still contribute to high energy costs when left on unnecessarily.<\/p>\n\n<p>The challenge lies in the fact that corridors are intermittently occupied, with periods of high foot traffic interspersed with times of vacancy. Traditional manual lighting controls can lead to lights being left on during these vacant periods, resulting in unnecessary energy waste.<\/p>\n\n<p>By integrating our occupancy sensors into your corridor lighting system, you can ensure that lights are only on when needed, saving energy and reducing costs. Our sensors, including wall and ceiling-mounted options, are designed to comply with US Energy Codes, making them an essential component in meeting energy efficiency requirements for commercial buildings.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Cumpra os C\u00f3digos de Energia<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>O International Energy Conservation Code (IECC) \u00e9 um c\u00f3digo modelo desenvolvido pelo International Code Council (ICC) para estabelecer requisitos m\u00ednimos de design e constru\u00e7\u00e3o para a efici\u00eancia energ\u00e9tica nos edif\u00edcios. O IECC \u00e9 atualizado a cada tr\u00eas anos para incorporar as \u00faltimas pr\u00e1ticas e tecnologias de conserva\u00e7\u00e3o de energia.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC, Por Que Deve Preocupar-Se<\/h3>\n\n<p>O IECC \u00e9 amplamente adotado por estados e munic\u00edpios em todo os Estados Unidos. O IECC abrange v\u00e1rios aspetos do uso de energia, incluindo o envelope do edif\u00edcio (paredes, tetos e janelas), sistemas de aquecimento e arrefecimento, e sistemas de ilumina\u00e7\u00e3o.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>O IECC exige controlos de ilumina\u00e7\u00e3o espec\u00edficos, como sensores de ocupa\u00e7\u00e3o, para minimizar o desperd\u00edcio de energia em espa\u00e7os desocupados em v\u00e1rias \u00e1reas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>O padr\u00e3o ANSI\/ASHRAE\/IES 90.1, Padr\u00e3o de Energia para Locais e Edif\u00edcios Exceto Edif\u00edcios Resenciais de Baixa Eleva\u00e7\u00e3o, \u00e9 um padr\u00e3o de energia amplamente reconhecido, publicado pela American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1, Por Que Deve Preocupar-Se<\/h3>\n\n<p>O ASHRAE 90.1 \u00e9 usado como refer\u00eancia para os c\u00f3digos de energia de edif\u00edcios em todo os Estados Unidos e serve como caminho de conformidade dentro do IECC, que descreve os requisitos m\u00ednimos para o desempenho energ\u00e9tico eficiente dos componentes de edif\u00edcios comerciais, incluindo envelopes de edif\u00edcios, sistemas HVAC, sistemas de aquecimento de \u00e1gua e sistemas de ilumina\u00e7\u00e3o. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>O padr\u00e3o ASHRAE 90.1 especifica as densidades de pot\u00eancia de ilumina\u00e7\u00e3o m\u00e1ximas permitidas e os requisitos m\u00ednimos de controlo de ilumina\u00e7\u00e3o, incluindo o uso de sensores de ocupa\u00e7\u00e3o em \u00e1reas espec\u00edficas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>O T\u00edtulo 24, parte 6 do California Building Standards Code, oficialmente conhecido como Building Energy Efficiency Standards for Residential and Nonresidential Buildings, \u00e9 administrado pela California Energy Commission e \u00e9 atualizado periodicamente para refletir novas tecnologias e m\u00e9todos de efici\u00eancia energ\u00e9tica.<\/p>\n\n<h3 class=\"wp-block-heading\">T\u00edtulo 24, Por Que Deve Preocupar-Se<\/h3>\n\n<p>O T\u00edtulo 24 \u00e9 conhecido pelos seus requisitos rigorosos, frequentemente considerados mais rigorosos do que os encontrados em muitos outros c\u00f3digos de energia em todo os Estados Unidos. O T\u00edtulo 24 exige padr\u00f5es rigorosos de desempenho energ\u00e9tico para todos os aspetos da constru\u00e7\u00e3o de edif\u00edcios, o que inclui aquecimento, ventila\u00e7\u00e3o, ar condicionado (HVAC), aquecimento de \u00e1gua e ilumina\u00e7\u00e3o.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>O T\u00edtulo 24 exige a instala\u00e7\u00e3o de sensores de ocupa\u00e7\u00e3o que ajustam a ilumina\u00e7\u00e3o com base na ocupa\u00e7\u00e3o do espa\u00e7o em \u00e1reas espec\u00edficas de edif\u00edcios comerciais para garantir que a energia n\u00e3o seja desperdi\u00e7ada.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Ado\u00e7\u00e3o do C\u00f3digo de Energia por Estado<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">Expanda para ver a tabela detalhada \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Estado<\/th><th>C\u00f3digo Comercial Atual<\/th><th>Categoria de Efici\u00eancia do C\u00f3digo Comercial<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alasca<\/td><td>Nenhum estadual<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Arizona<\/td><td>Governo local<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>2009 IECC e 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Calif\u00f3rnia<\/td><td>2022 Building Energy Efficiency Standards<\/td><td>90.1-2019<\/td><\/tr><tr><td>Colorado<\/td><td>Governo local<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Connecticut<\/td><td>2021 IECC e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>2018 IECC e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Distrito de Columbia<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Fl\u00f3rida<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Ge\u00f3rgia<\/td><td>2015 IECC e 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Hava\u00ed<\/td><td>Governo local<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>2018 IECC e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>2021 IECC e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Governo local<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Kentucky<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Louisiana<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Michigan<\/td><td>2015 IECC e 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Mississippi<\/td><td>Nenhum estadual<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Missouri<\/td><td>Governo local<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Montana<\/td><td>2021 IECC e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>2018 IECC e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>2018 IECC e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Hampshire<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>New Mexico<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>New York<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>North Carolina<\/td><td>2015 IECC e 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>North Dakota<\/td><td>Governo local<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Ohio<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>IECC 2006 e 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oregon<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pennsylvania<\/td><td>2018 IECC e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>South Carolina<\/td><td>2009 IECC e 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>South Dakota<\/td><td>Governo local<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2021 e 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>C\u00f3digo de Energia do Estado de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>2021 IECC e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>C\u00f3digo de Energia do Estado de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>West Virginia<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>2015 IECC e 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Governo local<\/td><td>Sem c\u00f3digo estadual<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ Quando uma emenda com impacto na efici\u00eancia energ\u00e9tica pode ser quantificada usando os Modelos de Edif\u00edcios Prot\u00f3tipo do DOE, ela foi inclu\u00edda na an\u00e1lise.<\/li>\n\n<li>Para estados que adotam tanto o IECC como o 90.1, o c\u00f3digo IECC \u00e9 geralmente analisado como o c\u00f3digo estadual atual neste estudo, exceto para estados com extensas emendas ao IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Solu\u00e7\u00f5es com Sensores<\/h4>\n\n<p>Descubra como a Rayzeek pode resolver os seus desafios de poupan\u00e7a de energia.<\/p>\n\n<a  href=\"https:\/\/staging.rayzeek.com\/pt\/produtos\"><div class=\"offering_button\"><p>Ver Todas as Ofertas<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-corridors\">Design Guide Key Concepts for Corridors<\/h2>\n\n<p>Designing an energy-efficient lighting control solution for corridors involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2.jpg\" alt=\"\" class=\"wp-image-18000\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>In a corridor, the primary goal is to ensure safe and well-lit passage for occupants while minimizing energy waste and all potential access points and the entire length of the corridor are covered by the sensors.  Here are some design considerations:<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>Sensor Placement<\/strong>: For long corridors, multiple sensors may be required. Ceiling-mounted sensors can be placed at regular intervals along the length of the corridor to ensure comprehensive coverage. Alternatively, wall-mounted sensors can be placed at both ends of the corridor, with their coverage areas overlapping in the middle to avoid any blind spots. Also, consider the height and range of the sensors to ensure they can effectively detect movement across the entire corridor.<\/li>\n\n<li><strong>Sensor Type<\/strong>: Depending on the ceiling height and the presence of any potential obstructions, either ceiling-mounted or wall-mounted sensors can be used. Rayzeek&#8217;s ceiling sensors offer automatic ON and full OFF functionality, while our wall sensors provide manual ON and full OFF functionality.<\/li>\n\n<li><strong>Additional Manual Controls<\/strong>: In addition to occupancy sensors, manual controls can be integrated for instances where manual override is necessary. These controls can be conveniently located near entrances or exits.<\/li>\n\n<li><strong>Avoiding False Triggers<\/strong>: Sensors should be placed such that they do not directly face doors leading to other spaces, external light sources and air vents, as this could lead to false triggers when movement is detected in these adjacent spaces.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Produtos e Solu\u00e7\u00f5es em Destaque<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/staging.rayzeek.com\/pt\/categoria-produto\/sensores-de-movimento\/wall-mount-motion-sensors\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Interruptores de Sensor de Parede<\/h3>\n\n<h4 class=\"wp-block-heading\">Interruptores de Sensor de Movimento RZ020\/021<\/h4>\n\n<ul class=\"wp-block-list\"><li>Op\u00e7\u00f5es de fia\u00e7\u00e3o de 2 fios, 3 fios, 4 fios <\/li>\n\n<li>Ocupa\u00e7\u00e3o, Vac\u00e2ncia, Ligar\/Desligar Manual<\/li>\n\n<li>Controlo de tempo de atraso e luz ambiente ajust\u00e1veis<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/staging.rayzeek.com\/pt\/categoria-produto\/sensores-de-movimento-sem-fios\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensores de Parede Sem Fios Multi-localiza\u00e7\u00e3o<\/h3>\n\n<h4 class=\"wp-block-heading\">Kits RZ020A\/021A + RZ022W<\/h4>\n\n<ul class=\"wp-block-list\"><li>Interruptor de sensor de ocupa\u00e7\u00e3o com fia\u00e7\u00e3o RZ021A\/022A<\/li>\n\n<li>Interruptor acompanhante sem fios (RZ022W) para controlo multi-localiza\u00e7\u00e3o<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/staging.rayzeek.com\/pt\/categoria-produto\/sensores-de-ocupacao\/montagem-no-teto\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensores de Ocupa\u00e7\u00e3o no Teto<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>Sensores de ocupa\u00e7\u00e3o com fia\u00e7\u00e3o<\/li>\n\n<li>Ligar automaticamente, desligar automaticamente <\/li>\n\n<li>Dispon\u00edvel para tens\u00e3o de linha e baixa tens\u00e3o<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Caracter\u00edsticas principais inclu\u00eddas:<\/h3>\n\n<ul class=\"wp-block-list\"><li>Controlo manual integrado para ligar\/desligar toda a ilumina\u00e7\u00e3o<\/li>\n\n<li>Sensores de vac\u00e2ncia (Apenas Manual ON): As luzes devem ser ligadas apenas manualmente<\/li>\n\n<li>Tempo de atraso ajust\u00e1vel, a ilumina\u00e7\u00e3o desliga-se automaticamente completamente ap\u00f3s 15 minutos<\/li>\n\n<li>Adicional: kits sem fios multi-localiza\u00e7\u00e3o para expandir o alcance de controlo sem refazer a fia\u00e7\u00e3o<\/li>\n\n<li>Adicional: m\u00faltiplas op\u00e7\u00f5es de fia\u00e7\u00e3o dispon\u00edveis tanto para novas constru\u00e7\u00f5es como para projetos de retrofit.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3.jpg\" alt=\"\" class=\"wp-image-18001\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Cumprimento das Disposi\u00e7\u00f5es Obrigat\u00f3rias<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC \u2013 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Controlos de sensor de ocupante<\/h4>\n\n<p>Devem ser instalados controlos de sensor de ocupante para controlar as luzes no espa\u00e7o.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Fun\u00e7\u00f5es de controlo do sensor de ocupante<\/h4>\n\n<ul class=\"wp-block-list\"><li>Liga\u00e7\u00e3o manual ou parcial a uma pot\u00eancia n\u00e3o superior a 50%.<\/li>\n\n<li>Desligamento completo dentro de 20 minutos ap\u00f3s todos os ocupantes terem sa\u00eddo do espa\u00e7o<\/li>\n\n<li>Um controlo manual para desligar as luzes.<\/li><\/ul>\n\n<p>Full automatic-on controls with no manual control are permitted in corridors where manual operation would endanger occupant safety or security.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405214-occupant-sensor-control-function-in-corridors\">C405.2.1.4 Occupant sensor control function in corridors.<\/h4>\n\n<p>Occupant sensor controls in corridors shall uniformly reduce lighting power to an occupied setpoint not more than 50 percent offull power within 20 minutes after all occupants have left the space.<\/p>\n\n<p>Exception: Corridors provided with less than two footcandles of illumination on the floor at the darkest point with all lights on.<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"9411-a-local-control\">9.4.1.1 a Controlo local<\/h4>\n\n<p>Deve haver um ou mais dispositivos de controlo manual de ilumina\u00e7\u00e3o que proporcionem controlo LIGAR e DESLIGAR<br>de toda a ilumina\u00e7\u00e3o no espa\u00e7o.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-g-automatic-reduction-control\">9.4.1.1 g Automatic reduction control<\/h4>\n\n<p>The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 h Automatic full OFF control<\/h4>\n\n<p>All lighting in the space shall be automatically shut off within 15 minutes of all occupants leaving the space.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-i-scheduled-shutoff\">9.4.1.1 i Scheduled shutoff<\/h4>\n\n<p>All lighting in the space shall be automatically shut off during periods when the space is scheduled to be unoccupied.<\/p>\n\n<p>** NOTE: At least one 9.4.1.1 h or 9.4.1.1 i shall be implemented.<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">Title 24 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) Controlos manuais de \u00e1rea.<\/h4>\n\n<p>Cada \u00e1rea delimitada por divis\u00f3rias que atinjam o teto deve dispor de controlos de ilumina\u00e7\u00e3o que permitam ligar e desligar manualmente a ilumina\u00e7\u00e3o nessa \u00e1rea.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Controlos de desligamento.<\/h4>\n\n<p>In corridors, lighting shall be controlled by Full or partial-OFF occupant sensing controls that separately reduce the lighting power in each space by at least 50 percent when the space is unoccupied. The occupant sensing controls shall be capable of automatically turning the lighting fully ON only in the separately controlled space, and shall be automatically activated from all designed paths of egress.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Ou\u00e7a-nos.<\/h3>\n\n<p>Deixe a Rayzeek ajudar a projetar e fornecer uma solu\u00e7\u00e3o de ilumina\u00e7\u00e3o personalizada para economia de energia para si.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/pt\/wp-json\/wp\/v2\/pages\/17996#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Formul\u00e1rio de contacto\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/pt\/wp-json\/wp\/v2\/pages\/17996#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Submeter\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"pt\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption.<\/p>","protected":false},"author":1,"featured_media":17998,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-17996","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Corridor Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/staging.rayzeek.com\/pt\/corridor-design-guide\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Corridor Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/staging.rayzeek.com\/pt\/corridor-design-guide\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide\",\"url\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide\",\"name\":\"Corridor Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T08:41:22+00:00\",\"dateModified\":\"2024-06-05T02:22:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/staging.rayzeek.com\/corridor-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide#primaryimage\",\"url\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/staging.rayzeek.com\/corridor-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/staging.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Corridor Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/staging.rayzeek.com\/#website\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/staging.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Corridor Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/staging.rayzeek.com\/pt\/corridor-design-guide","og_locale":"pt_PT","og_type":"article","og_title":"Corridor Energy Code Design Guide - Rayzeek","og_description":"Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption.","og_url":"https:\/\/staging.rayzeek.com\/pt\/corridor-design-guide","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:38+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Tempo estimado de leitura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/staging.rayzeek.com\/corridor-design-guide","url":"https:\/\/staging.rayzeek.com\/corridor-design-guide","name":"Corridor Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/staging.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/staging.rayzeek.com\/corridor-design-guide#primaryimage"},"image":{"@id":"https:\/\/staging.rayzeek.com\/corridor-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg","datePublished":"2024-05-21T08:41:22+00:00","dateModified":"2024-06-05T02:22:38+00:00","breadcrumb":{"@id":"https:\/\/staging.rayzeek.com\/corridor-design-guide#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/staging.rayzeek.com\/corridor-design-guide"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/staging.rayzeek.com\/corridor-design-guide#primaryimage","url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg","contentUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/staging.rayzeek.com\/corridor-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/staging.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Corridor Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/staging.rayzeek.com\/#website","url":"https:\/\/staging.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/staging.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/staging.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"},{"@type":"Organization","@id":"https:\/\/staging.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/staging.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages\/17996","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/comments?post=17996"}],"version-history":[{"count":11,"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages\/17996\/revisions"}],"predecessor-version":[{"id":18158,"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages\/17996\/revisions\/18158"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/media\/17998"}],"wp:attachment":[{"href":"https:\/\/staging.rayzeek.com\/pt\/wp-json\/wp\/v2\/media?parent=17996"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}