{"id":18027,"date":"2024-05-21T09:12:15","date_gmt":"2024-05-21T09:12:15","guid":{"rendered":"https:\/\/staging.rayzeek.com\/?page_id=18027"},"modified":"2024-06-05T02:22:38","modified_gmt":"2024-06-05T02:22:38","slug":"storage-room-design-guide","status":"publish","type":"page","link":"https:\/\/staging.rayzeek.com\/id\/storage-room-design-guide","title":{"rendered":"Panduan Desain Ruang Penyimpanan"},"content":{"rendered":"<div class=\"wp-block-cover alignfull rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-18031\" alt=\"\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg 1920w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-300x78.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-1024x267.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-768x200.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-1536x400.jpg 1536w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-18x5.jpg 18w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"storage-rooms\">storage rooms<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">Discover the energy-saving potential of storage rooms with Rayzeek&#8217;s occupancy sensor design guide.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5.jpg\" alt=\"\" class=\"wp-image-18030\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"maximize-energy-efficiency-in-storage-rooms-with-occupancy-sensors\">Maximize Energy Efficiency in Storage Rooms with Occupancy Sensors<\/h2>\n\n<p>Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents. Lighting in these areas is crucial for visibility and safety, but it can also be a significant source of energy waste. Traditional lighting systems in storage rooms are often left on unnecessarily, leading to high energy consumption and costs.<\/p>\n\n<p>Moreover, storage rooms are usually equipped with fluorescent or LED lights, which, while energy-efficient, can still consume a considerable amount of power when left on for extended periods. The sporadic and unpredictable nature of storage room usage further exacerbates this issue, as lights are often left on even when the room is unoccupied, leading to unnecessary energy waste.<\/p>\n\n<p>This energy wastage can be mitigated by using occupancy sensors. These devices automatically control lighting based on the presence or absence of people, ensuring lights are only on when needed. By installing occupancy sensors in storage rooms, businesses can significantly reduce their energy consumption, lower their utility bills, and contribute to a more sustainable environment.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Meet the Energy Codes<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>The International Energy Conservation Code (IECC) is a model code developed by the International Code Council (ICC) to establish minimum design and construction requirements for energy efficiency in buildings. The IECC is updated every three years to incorporate the latest in energy conservation practices and technologies.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC, Why You Should Care<\/h3>\n\n<p>IECC is widely adopted by states and municipalities across the United States. IECC covers various aspects of energy use, including the building envelope (walls, roofs, and windows), heating and cooling systems, and lighting systems.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>IECC mandates specific lighting controls, such as occupancy sensors, to minimize energy wastage in unoccupied spaces in various areas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>ANSI\/ASHRAE\/IES Standard 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, is a widely recognized energy standard published by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1, Why You Should Care<\/h3>\n\n<p>ASHRAE 90.1 is used as a benchmark for building energy codes across the United States and serves as a compliance path within the IECC which outlines minimum requirements for the energy-efficient performance of commercial buildings&#8217; components including building envelopes, HVAC systems, water heating systems, and lighting systems. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>ASHRAE 90.1 standard specifies maximum allowable lighting power densities and minimum lighting control requirements, including the use of occupancy sensors in specific areas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>Title 24, part 6 of the California Building Standards Code, officially known as the Building Energy Efficiency Standards for Residential and Nonresidential Buildings, Title 24 is administered by the California Energy Commission and is updated periodically to reflect new energy efficiency technologies and methods.<\/p>\n\n<h3 class=\"wp-block-heading\">Title 24, Why You Should Care<\/h3>\n\n<p>Title 24 is known for its rigorous requirements, often considered more stringent than those found in many other energy codes across the United States. Title 24 mandates strict energy performance standards for all aspects of building construction, which includes heating, ventilation, air conditioning (HVAC), water heating, and lighting.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Title 24 requires the installation of occupancy sensors that adjust lighting based on room occupancy in specific areas of commercial buildings to ensure that energy is not wasted.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Energy Code Adoption by State<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">Expand to see the detailed table \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>State<\/th><th>Current Commercial Code<\/th><th>Commercial Code Efficiency Category<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alaska<\/td><td>None statewide<\/td><td>No statewide code<\/td><\/tr><tr><td>Arizona<\/td><td>Home rule<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>2009 IECC and 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>California<\/td><td>2022 Building Energy Efficiency Standards<\/td><td>90.1-2019<\/td><\/tr><tr><td>Colorado<\/td><td>Home rule<\/td><td>No statewide code<\/td><\/tr><tr><td>Connecticut<\/td><td>2021 IECC and 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>2018 IECC and 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>District of Columbia<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Florida<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Georgia<\/td><td>2015 IECC and 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Hawaii<\/td><td>Home rule<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>2018 IECC and 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>2021 IECC and 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>2012 IECC and 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Home rule<\/td><td>No statewide code<\/td><\/tr><tr><td>Kentucky<\/td><td>2012 IECC and 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Louisiana<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>2015 IECC and 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>2018 IECC and 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Michigan<\/td><td>2015 IECC and 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Mississippi<\/td><td>None statewide<\/td><td>No statewide code<\/td><\/tr><tr><td>Missouri<\/td><td>Home rule<\/td><td>No statewide code<\/td><\/tr><tr><td>Montana<\/td><td>2021 IECC and 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>2018 IECC and 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>2018 IECC and 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Hampshire<\/td><td>2018 IECC and 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>New Mexico<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>New York<\/td><td>2018 IECC and 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>North Carolina<\/td><td>2015 IECC and 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>North Dakota<\/td><td>Home rule<\/td><td>No statewide code<\/td><\/tr><tr><td>Ohio<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>2006 IECC and 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oregon<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pennsylvania<\/td><td>2018 IECC and 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>2018 IECC and 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>South Carolina<\/td><td>2009 IECC and 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>South Dakota<\/td><td>Home rule<\/td><td>No statewide code<\/td><\/tr><tr><td>Tennessee<\/td><td>2021 IECC and 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>2015 IECC and 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>2018 Washington State Energy Code<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>2012 IECC and 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>2015 IECC and 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>2018 IECC and 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>2021 IECC and 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>2018 Washington State Energy Code<\/td><td>90.1-2019<\/td><\/tr><tr><td>West Virginia<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>2015 IECC and 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Home rule<\/td><td>No statewide code<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.<\/li>\n\n<li>For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Sensor Solutions<\/h4>\n\n<p>Find out how Rayzeek can solve your energy saving challenges.<\/p>\n\n<a  href=\"https:\/\/staging.rayzeek.com\/id\/products\"><div class=\"offering_button\"><p>View All Offerings<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-private-offices\">Design Guide Key Concepts for Private Offices<\/h2>\n\n<p>Designing an energy-efficient lighting control solution for private offices involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4.jpg\" alt=\"\" class=\"wp-image-18029\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>In a storage room, the primary areas that require lighting are the main walkways and the individual aisles between shelves.  Here are some guidelines to follow:<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>Main Walkways<\/strong>: Install ceiling occupancy sensors at regular intervals along the main walkways. These sensors should be set to Auto ON and Full OFF mode, ensuring that lights turn on automatically when someone enters the walkway and turn off when the area is vacant.<\/li>\n\n<li><strong>Individual Aisles<\/strong>: For individual aisles between shelves, consider installing wall occupancy sensors at the entrance of each aisle. These sensors can detect when someone enters the aisle and turn on the lights accordingly. Given the sporadic usage of these aisles, the sensors should be set to Manual ON and Full OFF mode. This means that the lights will only turn on when manually switched on but will turn off automatically when the aisle is vacant.<\/li>\n\n<li><strong>Entrance Area<\/strong>: The entrance area of the storage room should have a wall sensor switch that allows manual control of all lighting in the room. This switch can be used to turn all lights on or off as needed, providing an additional layer of control.<\/li>\n\n<li><strong>Sensor Placement Considerations<\/strong>: When placing sensors, ensure they are not located near air vents or other sources of movement that could trigger false positives. Also, ensure that the sensors&#8217; field of view is not obstructed by shelves or stored items.<\/li>\n\n<li><strong>Sensor Height<\/strong>: Consider the height of the sensor installation. Sensors should be installed at a height that allows for optimal coverage of the room, taking into account the height of stored items.<\/li>\n\n<li><strong>Manual Control<\/strong>: Incorporate manual controls to allow users to turn ON\/OFF all lighting when needed. This can be particularly useful in storage rooms where lighting may be required for extended periods during inventory checks or reorganization tasks.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Featured Products &amp; Solutions<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/staging.rayzeek.com\/id\/product-category\/motion-sensors\/wall-mount-motion-sensors\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Wall Sensor Switches<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ020\/021 Motion Sensor Switches<\/h4>\n\n<ul class=\"wp-block-list\"><li>2-wire, 3-wire, 4-wires wiring options <\/li>\n\n<li>Occupancy, Vacancy, Manual ON\/OFF<\/li>\n\n<li>Adjustive time delay and ambient light control<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/staging.rayzeek.com\/id\/product-category\/wireless-motion-sensors\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Multi-Location Wireless Wall Sensors<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ020A\/021A + RZ022W Kits<\/h4>\n\n<ul class=\"wp-block-list\"><li>Hardwired RZ021A\/022A occupancy sensor switch<\/li>\n\n<li>Wireless companion switch (RZ022W) for multi-location control<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/staging.rayzeek.com\/id\/product-category\/occupancy-sensors\/ceiling-mount\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Ceiling Occupancy Sensors<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>Hardwired occupancy sensors<\/li>\n\n<li>Auto ON, auto OFF <\/li>\n\n<li>Line voltage and Low voltage available<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Core features included:<\/h3>\n\n<ul class=\"wp-block-list\"><li>Integrated manual ON\/OFF control for all lighting<\/li>\n\n<li>Vacancy sensors (Manual ON only): Lights must be turned on manually only<\/li>\n\n<li>Adjustable time-delay, lighting is automatically turned full OFF after 15mins<\/li>\n\n<li>Additional: multi-location wireless kits to expand the control range without re-wring<\/li>\n\n<li>Additional: multiple wiring options available for both new constructions and retrofit projects.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3.jpg\" alt=\"\" class=\"wp-image-18028\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Meets the Mandatory Provisions<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC &#8211; 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Occupant sensor controls<\/h4>\n\n<p>Occupant sensor controls shall be installed to control lights in the space.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Occupant sensor control functions<\/h4>\n\n<ul class=\"wp-block-list\"><li>Manual on or partial on to no more than 50% power.<\/li>\n\n<li>Full off within 20 minutes after all occupants have left the space<\/li>\n\n<li>A manual control to turn off the lights.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 &#8211; 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"9411-a-local-control\">9.4.1.1 a Local control<\/h4>\n\n<p>There shall be one or more manual lighting control device that provides ON and OFF control<br>of all lighting in the space.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 H Automatic full OFF control <\/h4>\n\n<p>All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space<\/p>\n\n<p>Additionally, for storage rooms with sizes &lt;50 ft2:<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-b-restricted-to-manual-on\">9.4.1.1 b Restricted to manual ON<\/h4>\n\n<p>None of the lighting shall be automatically turned on<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">Title 24 &#8211; 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) Manual area controls.<\/h4>\n\n<p>Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Shut-OFF Controls.<\/h4>\n\n<p>Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:<\/p>\n\n<ul class=\"wp-block-list\"><li>A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or<\/li>\n\n<li>B. Partial-ON occupant sensing controls, or<\/li>\n\n<li>C. Vacancy sensing controls, where all lighting responds to a manual ON input only<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Let us hear you.<\/h3>\n\n<p>Let Rayzeek help design and deliver a bespoke energy-saving lighting solution for you.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/id\/wp-json\/wp\/v2\/pages\/18027#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/id\/wp-json\/wp\/v2\/pages\/18027#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Submit\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"id\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents.<\/p>","protected":false},"author":1,"featured_media":18031,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-18027","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Storage Room Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/staging.rayzeek.com\/id\/storage-room-design-guide\" \/>\n<meta property=\"og:locale\" content=\"id_ID\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Storage Room Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/staging.rayzeek.com\/id\/storage-room-design-guide\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Estimasi waktu membaca\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 menit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/staging.rayzeek.com\/storage-room-design-guide\",\"url\":\"https:\/\/staging.rayzeek.com\/storage-room-design-guide\",\"name\":\"Storage Room Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/staging.rayzeek.com\/storage-room-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/storage-room-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T09:12:15+00:00\",\"dateModified\":\"2024-06-05T02:22:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/staging.rayzeek.com\/storage-room-design-guide#breadcrumb\"},\"inLanguage\":\"id\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/staging.rayzeek.com\/storage-room-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/staging.rayzeek.com\/storage-room-design-guide#primaryimage\",\"url\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/staging.rayzeek.com\/storage-room-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/staging.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Storage Room Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/staging.rayzeek.com\/#website\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/staging.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"id\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Storage Room Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/staging.rayzeek.com\/id\/storage-room-design-guide","og_locale":"id_ID","og_type":"article","og_title":"Storage Room Energy Code Design Guide - Rayzeek","og_description":"Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents.","og_url":"https:\/\/staging.rayzeek.com\/id\/storage-room-design-guide","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:38+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Estimasi waktu membaca":"4 menit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/staging.rayzeek.com\/storage-room-design-guide","url":"https:\/\/staging.rayzeek.com\/storage-room-design-guide","name":"Storage Room Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/staging.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/staging.rayzeek.com\/storage-room-design-guide#primaryimage"},"image":{"@id":"https:\/\/staging.rayzeek.com\/storage-room-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","datePublished":"2024-05-21T09:12:15+00:00","dateModified":"2024-06-05T02:22:38+00:00","breadcrumb":{"@id":"https:\/\/staging.rayzeek.com\/storage-room-design-guide#breadcrumb"},"inLanguage":"id","potentialAction":[{"@type":"ReadAction","target":["https:\/\/staging.rayzeek.com\/storage-room-design-guide"]}]},{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/staging.rayzeek.com\/storage-room-design-guide#primaryimage","url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","contentUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/staging.rayzeek.com\/storage-room-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/staging.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Storage Room Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/staging.rayzeek.com\/#website","url":"https:\/\/staging.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/staging.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/staging.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"id"},{"@type":"Organization","@id":"https:\/\/staging.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/staging.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/staging.rayzeek.com\/id\/wp-json\/wp\/v2\/pages\/18027","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/staging.rayzeek.com\/id\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/staging.rayzeek.com\/id\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/id\/wp-json\/wp\/v2\/comments?post=18027"}],"version-history":[{"count":4,"href":"https:\/\/staging.rayzeek.com\/id\/wp-json\/wp\/v2\/pages\/18027\/revisions"}],"predecessor-version":[{"id":18153,"href":"https:\/\/staging.rayzeek.com\/id\/wp-json\/wp\/v2\/pages\/18027\/revisions\/18153"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/id\/wp-json\/wp\/v2\/media\/18031"}],"wp:attachment":[{"href":"https:\/\/staging.rayzeek.com\/id\/wp-json\/wp\/v2\/media?parent=18027"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}