{"id":18018,"date":"2024-05-21T09:01:51","date_gmt":"2024-05-21T09:01:51","guid":{"rendered":"https:\/\/staging.rayzeek.com\/?page_id=18018"},"modified":"2024-06-05T02:22:35","modified_gmt":"2024-06-05T02:22:35","slug":"restroom-design-guide","status":"publish","type":"page","link":"https:\/\/staging.rayzeek.com\/de\/toiletten-design-richtlinie","title":{"rendered":"Leitfaden zur BadezimmGestaltung"},"content":{"rendered":"<div class=\"wp-block-cover alignfull is-light rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-18024\" alt=\"\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg 1920w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner-300x78.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner-1024x267.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner-768x200.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner-1536x400.jpg 1536w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner-18x5.jpg 18w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"restrooms\">Toiletten<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">Entdecken Sie unseren Energiesparleitfaden f\u00fcr Toiletten, der Ihnen hilft, Belegungssensorl\u00f6sungen f\u00fcr eine effiziente Beleuchtungssteuerung gem\u00e4\u00df den US-Energievorschriften zu verstehen und umzusetzen.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5.jpg\" alt=\"\" class=\"wp-image-18022\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"maximize-energy-efficiency-in-restrooms-with-occupancy-sensors\">Maximieren Sie die Energieeffizienz in Toiletten mit Belegungssensoren<\/h2>\n\n<p>Toiletten in Gewerbegeb\u00e4uden sind h\u00e4ufig genutzte R\u00e4ume, die oft auch dann beleuchtet bleiben, wenn sie nicht besetzt sind, was zu erheblicher Energieverschwendung f\u00fchrt. Diese R\u00e4ume verwenden in der Regel Hochintensit\u00e4tsbeleuchtungsk\u00f6rper, die eine erhebliche Menge an Energie verbrauchen. Die sporadische und unvorhersehbare Nutzung der Toiletten versch\u00e4rft dieses Problem zus\u00e4tzlich, da die Beleuchtung oft unn\u00f6tigerweise w\u00e4hrend der Nichtnutzungszeiten eingeschaltet bleibt.<\/p>\n\n<p>Angesichts dieser Faktoren ist das Potenzial f\u00fcr Energieeinsparungen in Toiletten erheblich. Durch die Implementierung von Belegungssensorl\u00f6sungen k\u00f6nnen gewerbliche Einrichtungen ihren Energieverbrauch f\u00fcr die Beleuchtung erheblich reduzieren. Belegungssensoren erkennen die An- oder Abwesenheit von Personen und steuern die Beleuchtung entsprechend automatisch, sodass das Licht nur eingeschaltet ist, wenn es ben\u00f6tigt wird. Dies spart nicht nur Energie, sondern verl\u00e4ngert auch die Lebensdauer der Beleuchtungsk\u00f6rper, was zu weiteren Kosteneinsparungen f\u00fchrt.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Einhaltung der Energievorschriften<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>Der International Energy Conservation Code (IECC) ist ein Modellcode, der vom International Code Council (ICC) entwickelt wurde, um Mindestanforderungen an Entwurf und Bau f\u00fcr die Energieeffizienz von Geb\u00e4uden festzulegen. Der IECC wird alle drei Jahre aktualisiert, um die neuesten Praktiken und Technologien der Energiesparung zu ber\u00fccksichtigen.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC: Warum es Sie interessieren sollte<\/h3>\n\n<p>Der IECC wird von den US-Bundesstaaten und Gemeinden weithin \u00fcbernommen. Der IECC deckt verschiedene Aspekte des Energieverbrauchs ab, einschlie\u00dflich der Geb\u00e4udeh\u00fclle (W\u00e4nde, D\u00e4cher und Fenster), Heiz- und K\u00fchlsysteme sowie Beleuchtungssysteme.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Der IECC schreibt spezifische Beleuchtungssteuerungen vor, wie z. B. Belegungssensoren, um Energieverschwendung in unbesetzten R\u00e4umen in verschiedenen Bereichen zu minimieren.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>ANSI\/ASHRAE\/IES Standard 90.1, Energienorm f\u00fcr Standorte und Geb\u00e4ude mit Ausnahme von niedrigen Wohngeb\u00e4uden, ist eine weithin anerkannte Energienorm, die von der American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) ver\u00f6ffentlicht wird.<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1: Warum es Sie interessieren sollte<\/h3>\n\n<p>ASHRAE 90.1 dient als Referenzwert f\u00fcr Geb\u00e4ude-Energievorschriften in den gesamten USA und ist ein Konformit\u00e4tsweg innerhalb des IECC, der Mindestanforderungen an die energieeffiziente Leistung von Komponenten gewerblicher Geb\u00e4ude skizziert, einschlie\u00dflich Geb\u00e4udeh\u00fcllen, HLK-Systemen, Warmwassersystemen und Beleuchtungssystemen. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Die Norm ASHRAE 90.1 legt maximal zul\u00e4ssige Beleuchtungsleistungsdichten und Mindestanforderungen an die Beleuchtungssteuerung fest, einschlie\u00dflich der Verwendung von Belegungssensoren in bestimmten Bereichen.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>Title 24, Teil 6 des California Building Standards Code, offiziell bekannt als die Building Energy Efficiency Standards for Residential and Nonresidential Buildings (Geb\u00e4udeenergieeffizienzstandards f\u00fcr Wohn- und Nichtwohngeb\u00e4ude), wird von der California Energy Commission verwaltet und regelm\u00e4\u00dfig aktualisiert, um neue Energieeffizienztechnologien und -methoden widerzuspiegeln.<\/p>\n\n<h3 class=\"wp-block-heading\">Title 24: Warum es Sie interessieren sollte<\/h3>\n\n<p>Title 24 ist f\u00fcr seine strengen Anforderungen bekannt, die oft als strenger angesehen werden als die vieler anderer Energievorschriften in den USA. Title 24 schreibt strenge Energiestandards f\u00fcr alle Aspekte des Geb\u00e4udebaus vor, einschlie\u00dflich Heizung, L\u00fcftung, Klimaanlage (HLK), Warmwasserbereitung und Beleuchtung.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Title 24 verlangt die Installation von Belegungssensoren, die die Beleuchtung basierend auf der Raumnutzung in bestimmten Bereichen gewerblicher Geb\u00e4ude anpassen, um sicherzustellen, dass keine Energie verschwendet wird.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">\u00dcbernahme der Energievorschriften nach Bundesstaat<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">Erweitern, um die detaillierte Tabelle anzuzeigen \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Bundesstaat<\/th><th>Aktuelle Gewerbliche Vorschrift<\/th><th>Effizienzkategorie der Gewerblichen Vorschrift<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alaska<\/td><td>Keine bundesstaatliche Vorschrift<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Arizona<\/td><td>Home Rule<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>2009 IECC und 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kalifornien<\/td><td>2022 Building Energy Efficiency Standards<\/td><td>90.1-2019<\/td><\/tr><tr><td>Colorado<\/td><td>Home Rule<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Connecticut<\/td><td>2021 IECC und 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>2018 IECC und 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>District of Columbia<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Florida<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Georgia<\/td><td>2015 IECC und 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Hawaii<\/td><td>Home Rule<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>2018 IECC und 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>2021 IECC und 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>2012 IECC und 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Home Rule<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Kentucky<\/td><td>2012 IECC und 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Louisiana<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>2015 IECC und 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>2018 IECC und 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Michigan<\/td><td>2015 IECC und 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Mississippi<\/td><td>Keine bundesstaatliche Vorschrift<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Missouri<\/td><td>Home Rule<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Montana<\/td><td>2021 IECC und 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>2018 IECC und 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>2018 IECC und 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Hampshire<\/td><td>2018 IECC und 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>New Mexico<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>New York<\/td><td>2018 IECC und 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>North Carolina<\/td><td>2015 IECC und 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>North Dakota<\/td><td>Home Rule<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Ohio<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>2006 IECC und 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oregon<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pennsylvania<\/td><td>2018 IECC und 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>2018 IECC und 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>South Carolina<\/td><td>2009 IECC und 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>South Dakota<\/td><td>Home Rule<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Tennessee<\/td><td>2021 IECC und 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>2015 IECC und 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>Washington State Energiecode 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>2012 IECC und 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>2015 IECC und 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>2018 IECC und 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>Washington State Energiecode 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>West Virginia<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>2015 IECC und 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Home Rule<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ Wenn eine \u00c4nderung, die die Energieeffizienz beeinflusst, mit DOE-Prototypgeb\u00e4udemodellen quantifiziert werden konnte, wurde sie in die Analyse einbezogen.<\/li>\n\n<li>F\u00fcr Staaten, die sowohl den IECC als auch 90.1 annehmen, wird in dieser Studie in der Regel der IECC-Code als aktueller Code des Staates analysiert, mit Ausnahme von Staaten mit umfangreichen \u00c4nderungen am IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Sensorl\u00f6sungen<\/h4>\n\n<p>Erfahren Sie, wie Rayzeek Ihre Herausforderungen bei der Energieeinsparung l\u00f6sen kann.<\/p>\n\n<a  href=\"https:\/\/staging.rayzeek.com\/de\/produkte\"><div class=\"offering_button\"><p>Alle Angebote anzeigen<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-restrooms\">Wichtige Konzepte des Entwurfsleitfadens f\u00fcr Waschr\u00e4ume<\/h2>\n\n<p>Die Gestaltung einer energieeffizienten Beleuchtungssteuerungsl\u00f6sung f\u00fcr Waschr\u00e4ume erfordert die strategische Platzierung von Anwesenheitssensoren, um eine vollst\u00e4ndige Abdeckung des Raums zu gew\u00e4hrleisten.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2.jpg\" alt=\"\" class=\"wp-image-18019\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>Indem Sie diese Richtlinien befolgen, k\u00f6nnen Unternehmen eine energieeffiziente Beleuchtungssteuerungsl\u00f6sung f\u00fcr Waschr\u00e4ume schaffen, die Energieverschwendung reduziert und die Wartungskosten senkt:<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>Abdeckung des Eingangs<\/strong>: Installieren Sie einen Wand-Anwesenheitssensor in der N\u00e4he des Eingangs, um zu erkennen, wenn jemand den Waschraum betritt. Dieser Sensor sollte hoch genug positioniert sein, um Behinderungen durch die T\u00fcr zu vermeiden, und sollte nicht direkt auf den Eingang gerichtet sein, um Fehlausl\u00f6sungen durch Bewegungen au\u00dferhalb des Waschraums zu vermeiden.<\/li>\n\n<li><strong>Kabinenabdeckung<\/strong>: Je nach Kundenpr\u00e4ferenz bez\u00fcglich Privatsph\u00e4re k\u00f6nnen Kabinen entweder durch einen Sensor abgedeckt werden oder nicht. Wenn Kabinen nicht durch einen Sensor abgedeckt sind, programmieren Sie eine l\u00e4ngere Timeout-Zeit (15 oder 20 Minuten), um zu verhindern, dass die Beleuchtung ausgeht, wenn sich jemand in der Kabine befindet. Wenn einzelne Kabinensensoren verwendet werden, sollten sie so installiert werden, dass sie keine Bewegungen au\u00dferhalb der Kabine erkennen, um Fehlausl\u00f6sungen zu vermeiden.<\/li>\n\n<li><strong>Waschbecken- und Spiegelbereich<\/strong>: Installieren Sie einen Decken-Pr\u00e4senzsensor \u00fcber dem Waschbecken- und Spiegelbereich. Dieser Sensor sollte so positioniert werden, dass er den gesamten Bereich abdeckt und die Beleuchtung eingeschaltet bleibt, wenn jemand das Waschbecken oder den Spiegel benutzt.<\/li>\n\n<li><strong>Vermeidung von Luftausl\u00e4ssen<\/strong>: Montieren Sie keine Sensoren in der N\u00e4he von Luftausl\u00e4ssen, da die Vibration und der Luftstrom die Wirksamkeit des Sensors verringern k\u00f6nnen. PIR-Sensoren sollten nicht weniger als 1,2 m von einem Luftauslass entfernt sein, und Ultraschallsensoren sollten nicht weniger als 1,8 m von einem Luftauslass entfernt sein.<\/li>\n\n<li><strong>Manuelle Steuerung<\/strong>: Integrieren Sie eine manuelle Steuerung zum EIN-\/AUSschalten der gesamten Beleuchtung mit unseren Pr\u00e4senz-\/Abwesenheitssensoren. Dies erm\u00f6glicht eine manuelle \u00dcbersteuerung des Beleuchtungssystems bei Bedarf.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Ausgew\u00e4hlte Produkte &amp; L\u00f6sungen<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/staging.rayzeek.com\/de\/produkt-kategorie-2\/motion-sensors\/wall-mount-motion-sensors\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Wandsensor-Schalter<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ020\/021 Bewegungssensor-Schalter<\/h4>\n\n<ul class=\"wp-block-list\"><li>2-Draht-, 3-Draht-, 4-Draht-Verdrahtungsoptionen <\/li>\n\n<li>Pr\u00e4senz, Abwesenheit, Manuell EIN\/AUS<\/li>\n\n<li>Einstellbare Zeitverz\u00f6gerung und Umgebungslichtsteuerung<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/staging.rayzeek.com\/de\/produkt-kategorie-2\/wireless-motion-sensors\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Kabellose Mehrfachpositions-Wandsensoren<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ020A\/021A + RZ022W Kits<\/h4>\n\n<ul class=\"wp-block-list\"><li>Verkabelter RZ021A\/022A Pr\u00e4senzsensor-Schalter<\/li>\n\n<li>Kabelloser Begleitschalter (RZ022W) f\u00fcr Mehrfachpositionssteuerung<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/staging.rayzeek.com\/de\/produkt-kategorie-2\/anwesenheitssensoren\/ceiling-mount\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Decken-Pr\u00e4senzsensoren<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>Verkabelte Pr\u00e4senzsensoren<\/li>\n\n<li>Automatisch EIN, automatisch AUS <\/li>\n\n<li>Netzspannung und Niederspannung verf\u00fcgbar<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Kernfunktionen enthalten:<\/h3>\n\n<ul class=\"wp-block-list\"><li>Integrierte manuelle EIN\/AUS-Steuerung f\u00fcr die gesamte Beleuchtung<\/li>\n\n<li>Abwesenheitssensoren (nur Manuell EIN): Lichter m\u00fcssen nur manuell eingeschaltet werden<\/li>\n\n<li>Einstellbare Zeitverz\u00f6gerung, die Beleuchtung wird nach 15 Minuten automatisch vollst\u00e4ndig AUSgeschaltet<\/li>\n\n<li>Zus\u00e4tzlich: kabellose Mehrfachpositionskits zur Erweiterung des Steuerungsbereichs ohne Neuverkabelung<\/li>\n\n<li>Zus\u00e4tzlich: mehrere Verdrahtungsoptionen sowohl f\u00fcr Neubauten als auch f\u00fcr Nachr\u00fcstprojekte verf\u00fcgbar.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6.jpg\" alt=\"\" class=\"wp-image-18023\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Erf\u00fcllt die zwingenden Bestimmungen<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC \u2013 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Personenensor-Steuerungen<\/h4>\n\n<p>Personensensor-Steuerungen sollen installiert werden, um die Beleuchtung im Raum zu steuern.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Funktionen der Personensensor-Steuerung<\/h4>\n\n<ul class=\"wp-block-list\"><li>Manuell EIN oder Teil-EIN mit maximal 50% Leistung.<\/li>\n\n<li>Vollst\u00e4ndiges AUS innerhalb von 20 Minuten nachdem alle Personen den Raum verlassen haben<\/li>\n\n<li>Eine manuelle Steuerung zum Ausschalten der Beleuchtung.<\/li><\/ul>\n\n<p>**Vollautomatische EIN-Steuerungen ohne manuelle Steuerung sind in Toilettenr\u00e4umen erlaubt, in denen die manuelle Bedienung die Sicherheit oder den Schutz der Personen gef\u00e4hrden w\u00fcrde.<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 \u2013 2022<\/h3>\n\n<p>Toilettenr\u00e4ume m\u00fcssen ebenfalls durch Personensensoren gesteuert werden.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 H Automatische Voll-AUS-Steuerung <\/h4>\n\n<p>Die gesamte Beleuchtung im Raum muss innerhalb von 20 Minuten nach dem Verlassen des Raums durch alle Personen automatisch abgeschaltet werden<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">Title 24 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) Manuelle Bereichssteuerungen.<\/h4>\n\n<p>Jeder durch raumhohe Trennw\u00e4nde begrenzte Bereich muss Beleuchtungssteuerungen vorsehen, die es erm\u00f6glichen, die Beleuchtung in diesem Bereich manuell ein- und auszuschalten.<\/p>\n\n<p>** Toilettenr\u00e4ume mit zwei oder mehr Kabinen k\u00f6nnen eine manuelle Steuerung verwenden, die f\u00fcr unbefugtes Personal nicht zug\u00e4nglich ist.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Ausschalt-Steuerungen.<\/h4>\n\n<p>Die Beleuchtung muss mit Personen-anwesenheitssensor-Steuerungen gesteuert werden, um die gesamte Beleuchtung in 20 Minuten oder weniger automatisch AUSzuschalten, nachdem der Steuerungsbereich nicht mehr belegt ist, und zwar entweder als:<\/p>\n\n<ul class=\"wp-block-list\"><li>A. Personen-anwesenheitssensor-Steuerungen (sofern 130.1(b) nicht die Mehrstufige Beleuchtungssteuerung erfordert); oder<\/li>\n\n<li>B. Teil-EIN Personen-anwesenheitssensor-Steuerungen, oder<\/li>\n\n<li>C. Anwesenheitserkennungs-Steuerungen, bei denen die gesamte Beleuchtung nur auf eine manuelle EINGABE reagiert<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Lassen Sie uns von Ihnen h\u00f6ren.<\/h3>\n\n<p>Lassen Sie Rayzeek Ihnen bei der Planung und Bereitstellung einer ma\u00dfgeschneiderten energiesparenden Beleuchtungsl\u00f6sung helfen.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/de\/wp-json\/wp\/v2\/pages\/18018#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Kontaktformular\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/de\/wp-json\/wp\/v2\/pages\/18018#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Absenden\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"de\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Restrooms in commercial buildings are frequently used spaces that often remain lit even when unoccupied, leading to significant energy wastage. These spaces typically use high-intensity lighting fixtures that consume substantial amounts of energy.<\/p>","protected":false},"author":1,"featured_media":18024,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-18018","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Restroom Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/staging.rayzeek.com\/de\/toiletten-design-richtlinie\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Restroom Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"Restrooms in commercial buildings are frequently used spaces that often remain lit even when unoccupied, leading to significant energy wastage. These spaces typically use high-intensity lighting fixtures that consume substantial amounts of energy.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/staging.rayzeek.com\/de\/toiletten-design-richtlinie\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"4\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/staging.rayzeek.com\/restroom-design-guide\",\"url\":\"https:\/\/staging.rayzeek.com\/restroom-design-guide\",\"name\":\"Restroom Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/staging.rayzeek.com\/restroom-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/restroom-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T09:01:51+00:00\",\"dateModified\":\"2024-06-05T02:22:35+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/staging.rayzeek.com\/restroom-design-guide#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/staging.rayzeek.com\/restroom-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/staging.rayzeek.com\/restroom-design-guide#primaryimage\",\"url\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/staging.rayzeek.com\/restroom-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/staging.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Restroom Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/staging.rayzeek.com\/#website\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/staging.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Restroom Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/staging.rayzeek.com\/de\/toiletten-design-richtlinie","og_locale":"de_DE","og_type":"article","og_title":"Restroom Energy Code Design Guide - Rayzeek","og_description":"Restrooms in commercial buildings are frequently used spaces that often remain lit even when unoccupied, leading to significant energy wastage. These spaces typically use high-intensity lighting fixtures that consume substantial amounts of energy.","og_url":"https:\/\/staging.rayzeek.com\/de\/toiletten-design-richtlinie","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:35+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"4\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/staging.rayzeek.com\/restroom-design-guide","url":"https:\/\/staging.rayzeek.com\/restroom-design-guide","name":"Restroom Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/staging.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/staging.rayzeek.com\/restroom-design-guide#primaryimage"},"image":{"@id":"https:\/\/staging.rayzeek.com\/restroom-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg","datePublished":"2024-05-21T09:01:51+00:00","dateModified":"2024-06-05T02:22:35+00:00","breadcrumb":{"@id":"https:\/\/staging.rayzeek.com\/restroom-design-guide#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/staging.rayzeek.com\/restroom-design-guide"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/staging.rayzeek.com\/restroom-design-guide#primaryimage","url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg","contentUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/staging.rayzeek.com\/restroom-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/staging.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Restroom Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/staging.rayzeek.com\/#website","url":"https:\/\/staging.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/staging.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/staging.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/staging.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/staging.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/pages\/18018","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/comments?post=18018"}],"version-history":[{"count":8,"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/pages\/18018\/revisions"}],"predecessor-version":[{"id":18154,"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/pages\/18018\/revisions\/18154"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/media\/18024"}],"wp:attachment":[{"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/media?parent=18018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}