{"id":17981,"date":"2024-05-21T08:20:43","date_gmt":"2024-05-21T08:20:43","guid":{"rendered":"https:\/\/staging.rayzeek.com\/?page_id=17981"},"modified":"2024-06-05T02:22:27","modified_gmt":"2024-06-05T02:22:27","slug":"conference-room-design-guide","status":"publish","type":"page","link":"https:\/\/staging.rayzeek.com\/de\/leitfaden-zur-gestaltung-von-konferenzraumen","title":{"rendered":"Konferenzraum-Designleitfaden"},"content":{"rendered":"<div class=\"wp-block-cover alignfull is-light rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-17983\" alt=\"\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg 1920w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-300x78.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-1024x267.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-768x200.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-1536x400.jpg 1536w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-18x5.jpg 18w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"conference-rooms\">Konferenzr\u00e4ume<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">Entdecken Sie das Energiesparpotenzial Ihres Konferenzraums mit Rayzeeks Anwesenheitssensor-Designtipps.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1.jpg\" alt=\"\" class=\"wp-image-17984\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"maximize-energy-efficiency-in-conference-rooms-with-occupancy-sensors\">Maximieren Sie die Energieeffizienz in Konferenzr\u00e4umen mit Anwesenheitssensoren<\/h2>\n\n<p>Konferenzr\u00e4ume sind ein wesentlicher Bestandteil jedes Gewerbegeb\u00e4udes und dienen als Dreh- und Angelpunkt f\u00fcr Meetings, Pr\u00e4sentationen und Brainstorming-Sitzungen. Diese R\u00e4ume sind oft mit leistungsstarker Beleuchtung ausgestattet, um die Sichtbarkeit w\u00e4hrend Pr\u00e4sentationen und Diskussionen zu gew\u00e4hrleisten. Aufgrund ihrer intermittierenden Nutzung sind sie jedoch anf\u00e4llig f\u00fcr hohe Energieverschwendung. Lichter bleiben oft eingeschaltet, wenn der Raum leer steht, was zu unn\u00f6tigem Energieverbrauch f\u00fchrt.<\/p>\n\n<p>Dar\u00fcber hinaus bedeutet die sporadische Nutzung von Konferenzr\u00e4umen, dass sie oft \u00fcber l\u00e4ngere Zeitr\u00e4ume leer stehen, was zu unn\u00f6tigem Energieverbrauch f\u00fchrt, wenn die Lichter eingeschaltet bleiben. Diese Verschwendung wirkt sich nicht nur auf die Energieeffizienz des Geb\u00e4udes aus, sondern tr\u00e4gt auch zu h\u00f6heren Betriebskosten bei.<\/p>\n\n<p>Mit den Anwesenheitssensoren von Rayzeek k\u00f6nnen Sie Ihren Konferenzraum in einen energieeffizienten Raum verwandeln, der die Anforderungen der Energievorschriften erf\u00fcllt und zu einer umweltfreundlicheren Umgebung beitr\u00e4gt.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Einhaltung der Energievorschriften<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>Der International Energy Conservation Code (IECC) ist ein Modellcode, der vom International Code Council (ICC) entwickelt wurde, um Mindestanforderungen an Entwurf und Bau f\u00fcr die Energieeffizienz von Geb\u00e4uden festzulegen. Der IECC wird alle drei Jahre aktualisiert, um die neuesten Praktiken und Technologien der Energiesparung zu ber\u00fccksichtigen.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC: Warum es Sie interessieren sollte<\/h3>\n\n<p>Der IECC wird von den US-Bundesstaaten und Gemeinden weithin \u00fcbernommen. Der IECC deckt verschiedene Aspekte des Energieverbrauchs ab, einschlie\u00dflich der Geb\u00e4udeh\u00fclle (W\u00e4nde, D\u00e4cher und Fenster), Heiz- und K\u00fchlsysteme sowie Beleuchtungssysteme.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Der IECC schreibt spezifische Beleuchtungssteuerungen vor, wie z. B. Belegungssensoren, um Energieverschwendung in unbesetzten R\u00e4umen in verschiedenen Bereichen zu minimieren.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>ANSI\/ASHRAE\/IES Standard 90.1, Energienorm f\u00fcr Standorte und Geb\u00e4ude mit Ausnahme von niedrigen Wohngeb\u00e4uden, ist eine weithin anerkannte Energienorm, die von der American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) ver\u00f6ffentlicht wird.<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1: Warum es Sie interessieren sollte<\/h3>\n\n<p>ASHRAE 90.1 dient als Referenzwert f\u00fcr Geb\u00e4ude-Energievorschriften in den gesamten USA und ist ein Konformit\u00e4tsweg innerhalb des IECC, der Mindestanforderungen an die energieeffiziente Leistung von Komponenten gewerblicher Geb\u00e4ude skizziert, einschlie\u00dflich Geb\u00e4udeh\u00fcllen, HLK-Systemen, Warmwassersystemen und Beleuchtungssystemen. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Die Norm ASHRAE 90.1 legt maximal zul\u00e4ssige Beleuchtungsleistungsdichten und Mindestanforderungen an die Beleuchtungssteuerung fest, einschlie\u00dflich der Verwendung von Belegungssensoren in bestimmten Bereichen.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>Title 24, Teil 6 des California Building Standards Code, offiziell bekannt als die Building Energy Efficiency Standards for Residential and Nonresidential Buildings (Geb\u00e4udeenergieeffizienzstandards f\u00fcr Wohn- und Nichtwohngeb\u00e4ude), wird von der California Energy Commission verwaltet und regelm\u00e4\u00dfig aktualisiert, um neue Energieeffizienztechnologien und -methoden widerzuspiegeln.<\/p>\n\n<h3 class=\"wp-block-heading\">Title 24: Warum es Sie interessieren sollte<\/h3>\n\n<p>Title 24 ist f\u00fcr seine strengen Anforderungen bekannt, die oft als strenger angesehen werden als die vieler anderer Energievorschriften in den USA. Title 24 schreibt strenge Energiestandards f\u00fcr alle Aspekte des Geb\u00e4udebaus vor, einschlie\u00dflich Heizung, L\u00fcftung, Klimaanlage (HLK), Warmwasserbereitung und Beleuchtung.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Title 24 verlangt die Installation von Belegungssensoren, die die Beleuchtung basierend auf der Raumnutzung in bestimmten Bereichen gewerblicher Geb\u00e4ude anpassen, um sicherzustellen, dass keine Energie verschwendet wird.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">\u00dcbernahme der Energievorschriften nach Bundesstaat<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">Erweitern, um die detaillierte Tabelle anzuzeigen \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Bundesstaat<\/th><th>Aktuelle Gewerbliche Vorschrift<\/th><th>Effizienzkategorie der Gewerblichen Vorschrift<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alaska<\/td><td>Keine bundesstaatliche Vorschrift<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Arizona<\/td><td>Home Rule<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>2009 IECC und 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kalifornien<\/td><td>2022 Building Energy Efficiency Standards<\/td><td>90.1-2019<\/td><\/tr><tr><td>Colorado<\/td><td>Home Rule<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Connecticut<\/td><td>2021 IECC und 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>2018 IECC und 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>District of Columbia<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Florida<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Georgia<\/td><td>2015 IECC und 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Hawaii<\/td><td>Home Rule<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>2018 IECC und 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>2021 IECC und 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>2012 IECC und 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Home Rule<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Kentucky<\/td><td>2012 IECC und 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Louisiana<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>2015 IECC und 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>2018 IECC und 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Michigan<\/td><td>2015 IECC und 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Mississippi<\/td><td>Keine bundesstaatliche Vorschrift<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Missouri<\/td><td>Home Rule<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Montana<\/td><td>2021 IECC und 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>2018 IECC und 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>2018 IECC und 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Hampshire<\/td><td>2018 IECC und 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>New Mexico<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>New York<\/td><td>2018 IECC und 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>North Carolina<\/td><td>2015 IECC und 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>North Dakota<\/td><td>Home Rule<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Ohio<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>2006 IECC und 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oregon<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pennsylvania<\/td><td>2018 IECC und 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>2018 IECC und 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>South Carolina<\/td><td>2009 IECC und 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>South Dakota<\/td><td>Home Rule<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><tr><td>Tennessee<\/td><td>2021 IECC und 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>2015 IECC und 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>Washington State Energiecode 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>2012 IECC und 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>2015 IECC und 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>2018 IECC und 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>2021 IECC und 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>Washington State Energiecode 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>West Virginia<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>2015 IECC und 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Home Rule<\/td><td>Keine bundesstaatliche Vorschrift<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ Wenn eine \u00c4nderung, die die Energieeffizienz beeinflusst, mit DOE-Prototypgeb\u00e4udemodellen quantifiziert werden konnte, wurde sie in die Analyse einbezogen.<\/li>\n\n<li>F\u00fcr Staaten, die sowohl den IECC als auch 90.1 annehmen, wird in dieser Studie in der Regel der IECC-Code als aktueller Code des Staates analysiert, mit Ausnahme von Staaten mit umfangreichen \u00c4nderungen am IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Sensorl\u00f6sungen<\/h4>\n\n<p>Erfahren Sie, wie Rayzeek Ihre Herausforderungen bei der Energieeinsparung l\u00f6sen kann.<\/p>\n\n<a  href=\"https:\/\/staging.rayzeek.com\/de\/produkte\"><div class=\"offering_button\"><p>Alle Angebote anzeigen<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-conference-rooms\">Designtipps: Schl\u00fcsselkonzepte f\u00fcr Konferenzr\u00e4ume<\/h2>\n\n<p>Die Gestaltung einer energieeffizienten Beleuchtungssteuerungsl\u00f6sung f\u00fcr Konferenzr\u00e4ume erfordert die strategische Platzierung von Anwesenheitssensoren, um eine umfassende Abdeckung des Raums zu gew\u00e4hrleisten.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3.jpg\" alt=\"\" class=\"wp-image-17986\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>Die Gestaltung eines energieeffizienten Beleuchtungssystems f\u00fcr einen Konferenzraum erfordert die strategische Platzierung von Anwesenheitssensoren, um eine umfassende Abdeckung zu gew\u00e4hrleisten. Hier sind einige Richtlinien, die Sie ber\u00fccksichtigen sollten:<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>Abdeckung des Eingangs<\/strong>: Installieren Sie einen wandmontierten Sensor in der N\u00e4he des Eingangs, um zu erkennen, wenn jemand den Raum betritt oder verl\u00e4sst. Dieser Sensor sollte hoch genug positioniert werden, um nicht durch die ge\u00f6ffnete T\u00fcr blockiert zu werden, und sollte nicht direkt auf den Eingang gerichtet sein, um Fehlausl\u00f6sungen durch Bewegungen au\u00dferhalb des Raums zu vermeiden.<\/li>\n\n<li><strong>Tischabdeckung<\/strong>: Platzieren Sie einen deckenmontierten Sensor \u00fcber dem Konferenztisch, um die Anwesenheit im Hauptbereich des Raums zu erkennen. Dieser Sensor sollte zentral positioniert werden, um eine umfassende Abdeckung zu gew\u00e4hrleisten.<\/li>\n\n<li><strong>Pr\u00e4sentationsbereich-Abdeckung<\/strong>: Wenn Ihr Konferenzraum einen dedizierten Pr\u00e4sentationsbereich hat, erw\u00e4gen Sie die Installation eines zus\u00e4tzlichen wandmontierten Sensors, um diesen Bereich abzudecken. Dieser Sensor sollte so positioniert werden, dass m\u00f6gliche Hindernisse wie Bildschirme oder Projektoren vermieden werden.<\/li>\n\n<li><strong>Wandsteuerung<\/strong>: Installieren Sie eine Wandsteuereinheit in der N\u00e4he des Eingangs zur manuellen \u00dcbersteuerung oder Anpassung der Beleuchtungseinstellungen. Diese Steuerung sollte beim Betreten oder Verlassen des Raums leicht zug\u00e4nglich sein.<\/li>\n\n<li><strong>Vermeidung von Hindernissen und Interferenzen<\/strong>: Stellen Sie sicher, dass Sensoren nicht in der N\u00e4he von Bel\u00fcftungs\u00f6ffnungen platziert werden, um Interferenzen durch Luftstr\u00f6mungen oder Vibrationen zu vermeiden. Ber\u00fccksichtigen Sie auch die H\u00f6he und Platzierung von M\u00f6beln, um die Sichtlinie des Sensors nicht zu blockieren.<\/li>\n\n<li><strong>Integration in bestehende Systeme<\/strong>: Unsere Anwesenheitssensoren k\u00f6nnen in bestehende Beleuchtungssysteme f\u00fcr einen nahtlosen Betrieb integriert werden. Sie k\u00f6nnen auch so programmiert werden, dass sie nach einer bestimmten Zeit der Inaktivit\u00e4t alle Lichter ausschalten, was die Energieeffizienz weiter verbessert.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Ausgew\u00e4hlte Produkte &amp; L\u00f6sungen<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/staging.rayzeek.com\/de\/produkt-kategorie-2\/bewegungssensoren\/wall-mount-motion-sensors\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Wandsensor-Schalter<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ020\/021 Bewegungssensor-Schalter<\/h4>\n\n<ul class=\"wp-block-list\"><li>2-Draht-, 3-Draht-, 4-Draht-Verdrahtungsoptionen <\/li>\n\n<li>Pr\u00e4senz, Abwesenheit, Manuell EIN\/AUS<\/li>\n\n<li>Einstellbare Zeitverz\u00f6gerung und Umgebungslichtsteuerung<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/staging.rayzeek.com\/de\/produkt-kategorie-2\/kabellose-bewegungssensoren\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Kabellose Mehrfachpositions-Wandsensoren<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ020A\/021A + RZ022W Kits<\/h4>\n\n<ul class=\"wp-block-list\"><li>Verkabelter RZ021A\/022A Pr\u00e4senzsensor-Schalter<\/li>\n\n<li>Kabelloser Begleitschalter (RZ022W) f\u00fcr Mehrfachpositionssteuerung<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/staging.rayzeek.com\/de\/produkt-kategorie-2\/anwesenheitssensoren\/deckenmontage\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Decken-Pr\u00e4senzsensoren<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>Verkabelte Pr\u00e4senzsensoren<\/li>\n\n<li>Automatisch EIN, automatisch AUS <\/li>\n\n<li>Netzspannung und Niederspannung verf\u00fcgbar<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Kernfunktionen enthalten:<\/h3>\n\n<ul class=\"wp-block-list\"><li>Integrierte manuelle EIN\/AUS-Steuerung f\u00fcr die gesamte Beleuchtung<\/li>\n\n<li>Abwesenheitssensoren (nur Manuell EIN): Lichter m\u00fcssen nur manuell eingeschaltet werden<\/li>\n\n<li>Einstellbare Zeitverz\u00f6gerung, die Beleuchtung wird nach 15 Minuten automatisch vollst\u00e4ndig AUSgeschaltet<\/li>\n\n<li>Zus\u00e4tzlich: kabellose Mehrfachpositionskits zur Erweiterung des Steuerungsbereichs ohne Neuverkabelung<\/li>\n\n<li>Zus\u00e4tzlich: mehrere Verdrahtungsoptionen sowohl f\u00fcr Neubauten als auch f\u00fcr Nachr\u00fcstprojekte verf\u00fcgbar.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4.jpg\" alt=\"\" class=\"wp-image-17982\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4.jpg 1000w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Erf\u00fcllt die zwingenden Bestimmungen<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC \u2013 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Personenensor-Steuerungen<\/h4>\n\n<p>Personensensor-Steuerungen sollen installiert werden, um die Beleuchtung im Raum zu steuern.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Funktionen der Personensensor-Steuerung<\/h4>\n\n<ul class=\"wp-block-list\"><li>Manuell EIN oder Teil-EIN mit maximal 50% Leistung.<\/li>\n\n<li>Vollst\u00e4ndiges AUS innerhalb von 20 Minuten nachdem alle Personen den Raum verlassen haben<\/li>\n\n<li>Eine manuelle Steuerung zum Ausschalten der Beleuchtung.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"9411-a-local-control\">9.4.1.1 a Lokale Steuerung<\/h4>\n\n<p>Es muss ein oder mehrere manuelle Beleuchtungssteuerungsger\u00e4te geben, die eine EIN- und AUS-Steuerung<br>der gesamten Beleuchtung im Raum erm\u00f6glichen.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-b-restricted-to-manual-on\">9.4.1.1 b Beschr\u00e4nkt auf manuell EIN<\/h4>\n\n<p>Keine der Beleuchtung darf automatisch eingeschaltet werden<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-c-restricted-to-partial-automatic-on\">9.4.1.1 c Beschr\u00e4nkt auf teilautomatisches EINSCHALTEN<\/h4>\n\n<p>Es darf h\u00f6chstens 50% der Beleuchtungsleistung f\u00fcr die Allgemeinbeleuchtung automatisch eingeschaltet werden<\/p>\n\n<p>** HINWEIS: Mindestens eine der Anforderungen 9.4.1.1 b oder 9.4.1.1 c muss implementiert werden.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 h Automatische vollst\u00e4ndige AUSSCHALT-Steuerung <\/h4>\n\n<p>Die gesamte Beleuchtung im Raum muss innerhalb von 20 Minuten nach dem Verlassen des Raums durch alle Personen automatisch abgeschaltet werden<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">Title 24 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) Manuelle Bereichssteuerungen.<\/h4>\n\n<p>Jeder durch raumhohe Trennw\u00e4nde begrenzte Bereich muss Beleuchtungssteuerungen vorsehen, die es erm\u00f6glichen, die Beleuchtung in diesem Bereich manuell ein- und auszuschalten.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Ausschalt-Steuerungen.<\/h4>\n\n<p>Die Beleuchtung muss mit Personen-anwesenheitssensor-Steuerungen gesteuert werden, um die gesamte Beleuchtung in 20 Minuten oder weniger automatisch AUSzuschalten, nachdem der Steuerungsbereich nicht mehr belegt ist, und zwar entweder als:<\/p>\n\n<ul class=\"wp-block-list\"><li>A. Personen-anwesenheitssensor-Steuerungen (sofern 130.1(b) nicht die Mehrstufige Beleuchtungssteuerung erfordert); oder<\/li>\n\n<li>B. Teil-EIN Personen-anwesenheitssensor-Steuerungen, oder<\/li>\n\n<li>C. Anwesenheitserkennungs-Steuerungen, bei denen die gesamte Beleuchtung nur auf eine manuelle EINGABE reagiert<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Lassen Sie uns von Ihnen h\u00f6ren.<\/h3>\n\n<p>Lassen Sie Rayzeek Ihnen bei der Planung und Bereitstellung einer ma\u00dfgeschneiderten energiesparenden Beleuchtungsl\u00f6sung helfen.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/de\/wp-json\/wp\/v2\/pages\/17981#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Kontaktformular\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/de\/wp-json\/wp\/v2\/pages\/17981#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Absenden\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"de\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Konferenzr\u00e4ume sind ein wesentlicher Bestandteil jedes Gewerbegeb\u00e4udes und dienen als Dreh- und Angelpunkt f\u00fcr Meetings, Pr\u00e4sentationen und Brainstorming-Sitzungen.<\/p>","protected":false},"author":1,"featured_media":17983,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-17981","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Conference Room Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/staging.rayzeek.com\/de\/leitfaden-zur-gestaltung-von-konferenzraumen\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Conference Room Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"Conference rooms are integral to the functioning of any commercial building, serving as the hub for meetings, presentations, and brainstorming sessions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/staging.rayzeek.com\/de\/leitfaden-zur-gestaltung-von-konferenzraumen\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"4\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide\",\"url\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide\",\"name\":\"Conference Room Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T08:20:43+00:00\",\"dateModified\":\"2024-06-05T02:22:27+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/staging.rayzeek.com\/conference-room-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide#primaryimage\",\"url\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/staging.rayzeek.com\/conference-room-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/staging.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Conference Room Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/staging.rayzeek.com\/#website\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/staging.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/staging.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/staging.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Conference Room Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/staging.rayzeek.com\/de\/leitfaden-zur-gestaltung-von-konferenzraumen","og_locale":"de_DE","og_type":"article","og_title":"Conference Room Energy Code Design Guide - Rayzeek","og_description":"Conference rooms are integral to the functioning of any commercial building, serving as the hub for meetings, presentations, and brainstorming sessions.","og_url":"https:\/\/staging.rayzeek.com\/de\/leitfaden-zur-gestaltung-von-konferenzraumen","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:27+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"4\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/staging.rayzeek.com\/conference-room-design-guide","url":"https:\/\/staging.rayzeek.com\/conference-room-design-guide","name":"Conference Room Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/staging.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/staging.rayzeek.com\/conference-room-design-guide#primaryimage"},"image":{"@id":"https:\/\/staging.rayzeek.com\/conference-room-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg","datePublished":"2024-05-21T08:20:43+00:00","dateModified":"2024-06-05T02:22:27+00:00","breadcrumb":{"@id":"https:\/\/staging.rayzeek.com\/conference-room-design-guide#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/staging.rayzeek.com\/conference-room-design-guide"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/staging.rayzeek.com\/conference-room-design-guide#primaryimage","url":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg","contentUrl":"https:\/\/staging.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/staging.rayzeek.com\/conference-room-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/staging.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Conference Room Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/staging.rayzeek.com\/#website","url":"https:\/\/staging.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/staging.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/staging.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/staging.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/staging.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/staging.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/pages\/17981","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/comments?post=17981"}],"version-history":[{"count":7,"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/pages\/17981\/revisions"}],"predecessor-version":[{"id":18159,"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/pages\/17981\/revisions\/18159"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/media\/17983"}],"wp:attachment":[{"href":"https:\/\/staging.rayzeek.com\/de\/wp-json\/wp\/v2\/media?parent=17981"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}